DX - ISOBUS
S
ET UP THE
ISOLINK
F3.1
N
AME
:
T
RAINING
D
EPARTMENT
D
ATE
:
2019.09
P
AGE
:
37/55
R
ÉFÉRENCE
:
T
ECHNICIAN
O
PERATING
M
ANUAL
DX
ISOBUS
I
ND
01
a)
Machine type :
Access the
ADVANCED SETTINGS
page
Select
Factory
Enter the PIN code 0035 and confirm
Press
Machine Options
Press marker ① to select machine type. Select :
WPB-DX S&G
(only option up to the isolink CMS104-002 rev
43 version)
WPB
–
DX W CONTROL
(Possible from DX serial number
18AC09105 and 18AE09104 and from Isolink version
CMS104-002 rev 51)
Press
ESC
to exit
b)
Angle senso
r + weighing coefficients
i.
Angle sensor
With the spreader connected, position the spreader level
before calibrating the angle sensor.
From the
ADVANCED SETTINGS
page, select
Actuators & Sensors
.
Enter the PIN code 1936 and confirm
Scroll through the
ATUATORS & SENSORS
menu with
to display the
Angle sensor
Once the spreader is level press the key
ii.
Weighing coefficients
Scroll through the
ATUATORS & SENSORS
menu with
to display the
Weigh Cell
page
Enter the values :
Tare point
et
High Point
Press
ESC
to exit
①