DX - ISOBUS
T
RIBORD ACTUATOR
D2.2
N
AME
:
T
RAINING
D
EPARTMENT
D
ATE
:
2019.09
P
AGE
:
24/55
R
ÉFÉRENCE
:
T
ECHNICIAN
O
PERATING
M
ANUAL
DX
ISOBUS
I
ND
01
3.
Display of malfunction alarms :
If there is no feedback from the actuator or if it is inactive, the
following alarm is triggered:
TRIBORD RIGHT ACTUATOR PROBLEM
4.
Diagnostics on the console :
From the
HOME
menu, make sure that the shutters are
closed
Access the
ADVANCED SETTINGS
menu with
Select
Diagnostics
And press the key
To check an actuator, perform a complete extension of the rod :
80 impulsions
± 2 and a
40 mm
stroke should be obtained
If there is a fault, the screen displays
Blocked
Not available
on DX
Tribord actuator
extension
control
Not available
on DX
Not available
on DX
Actuator status
Ok/Run
/Blocked
Tribord
actuator
Actuator return :
Rod extension :
Not available
on DX
Tribord actuator
retractation
control