Electric Connection
Heating Unit must be fix installed and permanently wired.
Use junction box of min IP 54.
Local norms and regulations must be respected! According connection diagram, observe VDE 0100!
All installation, maintenance and inspection works of the unit must be carried out by an authorised and qualified
electrician only.
Technical data:
Connections Controller / Pump
Connections Heating elemnt
Output Pump
Output Heaing element
STB
Dust/water protection
Heating range
3 x 1,5 mm²
3 x 1,5 mm²
230 V AC / stage 3 = 0,41 A / 93 W
0-3000 W
90°C opener/heating
IP 44
0°C to +10°C
Voltage supply
Voltage supply
Water pressure range
Water connection entry
Water connection exit
Size (l x b x h)
Weight
1x 230 V +/- 10% 50 Hz
1x 230 V +/- 10% 50 Hz
1 - 4 bar
¾"
¾"
70 x 60 x 30 cm
approx. 27 kg
Flow rate
of water circuit
given at 4-5 bar
Pressure
Mod. 671
water flow
Mod. 700
Mod. 723
water flow
Mod. 500
Mod. 520
water flow
Cattle/Horses
drinking bowls
water flow
Pig
drinking bowls
water flow
¾"
½"
4 bar
21 l/min
30 l/min
30 l/min
12 l/min
1,3 l/min
150 l/min*
90 l/min*
3 bar
16 l/min
27 l/min
27 l/min
11 l/min
1,1 l/min
2 bar
12 l/min
22,5 l/min
21 l/min
8 l/min
0,9 l/min
1 bar
6 l/min
14,5 l/min
10 l/min
4 l/min
0,7 l/min
* Theoretic values depend in practice on local circumstances and can result in lower values.
Example:
Local circumstances: 4 bar of pressure, ¾" water line (150 l/min)
Question:
How many cattle drinking bowls can be connected?
Calculation:
150 l/min : 12 l/min = 12,5 pieces
12,5 pieces x
2
(experimental value*) = 25 pieces
Answer:
25 pieces of cattle drinking bowls can be connected.
Water flow quantity depends on the following conditions:
Water pressure, length of pipes and cross sectional area as well as the quantity of reduction pieces and curves.
*Experimental value
is based on field test, which revealed that not all the drinking bowls are actionned at
the same
time. That’s why the result has to be multiplied with
factor two
.
Heating Unit must be used with two separate residual current devices (RCD): two-pole 30 mA (for the-
pump and for the heating element).
A damaged heating or pump can cause that the residual current circuit breaker triggers and the heating unit and the
pump are out of function. This leads that the water supply line risks to freeze due to a cold outside temperature.
Special and corresponding steps have to be taken at the spot by the user to protect it against freezing:
e.g. frost protection heating cables, warning system, etc.
Determination of Quantity of Drinking Bowls