Page 55
7-2
#7040748 - Revision A - September, 2016
Technical Data
MODEL UW-24
MODEL UW-24
Model UW-24
REFRIGERATOR
CHARGE
(R-134a Refrigerant)
NOTE:
Always check serial tag for exact charge
NORMAL OPERATING PRESSURES
Low Side
High Side
COMPRESSOR
Original/Service Compressor Amps
Original/Service Compressor BTU/H
DEFROST METHOD
THERMISTORS
Resistance/Ohms at 32°F
3.25 oz
10 psig to 36 psig
90 psig to 100 psig
~.65/~.65
706/706
“Off-Cycle Defrost”
Evap > High Offset temperature
before Compressor ON.
30000 - 33000