FLOORING
FRAMING
INNER COACH WALL
OUTER COACH WALL
B
A
A=12 3/4" + 1/8 - 0
B=12 3/4" + 1/8 - 0
4 & 6 Gallons
A=16 3/8" ± 1/16
B=16 3/8" ± 1/16
10, 12 & 16 Gallons
WATER HEATER AS VIEW FROM INSIDE R.V.
SECURE CHOCKS, ONE ON EACH SIDE, TIGHTLY AGAINST WATER HEATER JACKET
AND FASTEN TO VEHICLE FLOOR TO PREVENT MOVEMENT. CHOCKS SHOULD BE
APPROXIMATELY 2" X 2" X 6"
FRAMED OPENING
FLOOR
inStallatiOn inStructiOnS
Minimum clearance is 0” from combustible construction on sides, top, floor and rear
as listed in the installation
manual for your specific model
. Provide room for access to rear of heater for servicing.
Provide an opening flush with floor in outer wall of coach. Wall of coach should be framed as shown in Figure 1.
Maintain inside dimensions listed below. Do not install on carpet unless the carpet is covered by a metal or wood
shield covering the entire area underneath the water heater. If preferred, cut away the carpet from this area.
Chocks must be in place to secure rear of unit (See Figure 1A).
Figure 1
Figure 1A