- 33 -
Connectors
Check
name
type
Tester
Check condition
Normalcy
Estimation abnormality
point when NOT normal
+
–
+B
Voltage
A3
Earth
always
10~14V
Harness
GND
A18
Earth
always
Conduction
Harness
IG
Voltage
A6
Earth
Push-start
ACC→ON
0V→10~14V
Harness
RREG
A9
Earth
Connector B,C
Non-connection→
connection
No Conduction
→Conduction
Harness
HOOD
A8
Earth
Hood
close→open
No Conduction
→Conduction
Either
Hood SW, harness,
Sub-Harness
I1
I2
Hood SW
Push→Release
No Conduction
→Conduction
Either
Hood SW, Sub-Harness
Y1
Y2
Hood SW
Push→Release
No Conduction
→Conduction
Hood SW
PWI
Voltage
A1
Earth
Push-start
ACC→ON
0V→10~14V
Harness
A10
Earth
always
Conduction
Harness
List of wiring harness checks
A
B
C
F
G
H
I
Y
1
3
1
10
6
15 16
18
8 9
1
2
1
4
5
6
3
2 1