6. stoppInG the GenerAtor
1. Turn off the power switch of the electric equipment and
unplug the cord from the receptacle of the generator.
2. Allow the engine about 3 minutes to cool down at no-load
before stopping.
3. Turn the engine switch to the position ‘‘
o
’’ (OFF).
4. Close the fuel cock.
7. oIL sensor
•
The oil sensor detects the fall in oil level in the crankcase and automatically stops the engine when
the oil level falls below a predetermined level.
•
When engine has stopped automatically, switch off generator’s no-fuse breaker, and check the oil
level. Refill engine oil to the upper level as instructed on page 8 and restart the engine.
•
If the engine does not start by usual, consult your nearest Robin dealer or service shop.
note
If the engine doesn’t start by usual, consult your nearest Robin dealer or service shop.
Do not remove OIL SeNSOR PROBe when refilling with oil. Remove oil
filler cap on the opposite side of carburetor.