Page 15
2-12
#7040743 - Revision A - September, 2016
Electronic Control System
Built-In Wine Storage (BW) Series
Built-In Wine Storage (BW) Series
POSSIBLE WINE STORAGE ERROR/FAULT INDICATORS
All wine storage units are equipped with an audio-visual temperature and door alarm feature, as well as low voltage
wiring provisions to allow the alarm to be tied into a home security alarm system. This section explains the tempera-
ture/door alarm feature and the audio and/or visual error indicators that may alert a customer of a malfunction.
NOTE:
If the temperature alarm feature is tied into a home security system, the connections are made using the
security system’s logic. If problems occur between the wine storage unit and the security system, then a home
security system technician should be contacted.
Warm Temperature/Door Alarm
A warm temperature alarm can occur if either wine storage compartment remains warm for too long, causing several
consecutive maximum run-time cycles. A warm temperature alarm situation will cause the SERVICE indicator to
flash (See Figure 2-18), and an appropriate error code to be logged; power to the compressor and condenser fan is
also cut. If the temperature alarm feature has been enabled by pressing the ALARM key on the control panel, the
ALARM indicator will also flash, and the audible alarm will beep. (See Figure 2-19)
NOTE:
To clear the warm temperature/door alarm, the problem must be corrected, then press the POWER key to
switch the unit Off, then press it again to switch the unit back ON. (See Figure 2-20) Also see Clearing Error
Codes, later in this section.
Figure 2-18. Warm Temperature/Door Alarm, “SERVICE” Flashing
Figure 2-19. Warm Temperature Alarm with ALARM Feature Enabled:
“SERVICE” and “ALARM” Flashing with Audible Alarm Beeping
BEEP! BEEP! BEEP!
Figure 2-20. Clear Warm Temperature/Door Alarm - Press POWER Key to Off, Then again to ON
(Also see Clearing Error Codes, later in this section.)