background image

Page 5

Model 315I (UC Ice Maker)

Installation Information

2-5

#3757320 - Revision B - August, 2005

INSTALLATION

Installation Instructions  (Model 315IP - Drain Pump
Model)

1.

Place ice maker in front of installation location.
Level unit as described on previous page.

2.

Remove door with hinges, kickplate, lower stainless
steel face plate, control knob and control panel.

3.

Route inlet water line through back of compressor
area to front of unit, keeping tubing towards left
side.

4.

Locate coil of 3/8” I.D. plastic drain tubing secured
to back of unit.

5.

Route plastic drain tube to drain connection point.

NOTE:

Often an air gap is required by local codes

between the ice maker drain tube and the drain recep-
tacle.

6.

Plug power cord into wall outlet.

7.

Push ice maker into installation position.

8.

Cut inlet water line to required length.

NOTE:

It is recommended to flush the inlet water line

at this time by turning water supply on and letting the
water drain into a bucket.

9.

Place flare nut onto inlet water line, then flare end
of tube.

10. Attach flare nut to water valve inlet.

11. Turn water supply on and check for leaks.

12. Switch unit on and pour a couple of quarts of water

into ice storage bin.  The pump should start up and
pump water out.  Check for leaks.

13. Replace all parts removed in step 2.

PRE-INSTALLATION SPECIFICATIONS

(Model 315IP - Drain Pump Model)

NOTE: 

All

plumbing

must meet

local

codes.

Securing the Unit (Model 315I & 315IP)

Once the icemaker is installed, secure the unit to the
cabinet by inserting two #8 x 1/2” flat head screws (sup-
plied with the unit) through the holes in the flange of
each hinge.  

(See Figure 2-4)

Figure 2-4.  Securing Unit to Cabinet

Summary of Contents for 315I

Page 1: ...Installation Information 6 subzero com 800 222 7820 315 Service Manual...

Page 2: ...s are chemically bonded to the water mole cules referred to as dissolved solids and cannot be fil tered out Ice made by the model 315I will have a lower mineral content than the water it is made from...

Page 3: ...service purposes the finished floor should be pro tected with appropriate material Drain There are two 315I models with different drainage con figurations the model 315I and model 315IP The model 315I...

Page 4: ...r line through back of compressor area to front of unit keeping tubing towards left side 4 Route drain tube from drain waste receptacle through back of compressor area to front of unit keeping tubing...

Page 5: ...outlet 7 Push ice maker into installation position 8 Cut inlet water line to required length NOTE It is recommended to flush the inlet water line at this time by turning water supply on and letting th...

Page 6: ...through hinge into mounting holes and tighten Then move top right hinge to bottom left hinge mounting holes and insert two hinge mounting screws through hinge into mounting holes and tight en 7 Attac...

Page 7: ...ce making sure to not damage front of panel 2 Position plastic drilling template provided with unit on back of door panel flush with upper edge and side of door panel See Figure 2 8 NOTE The size of t...

Page 8: ...eeding to the hinge cover installation instructions NOTES DO NOT attempt to install the hinge covers before the 90 door stop pins are installed if used If the 90 stop pins are installed it will be nec...

Page 9: ...h button out See Figure 2 13 5 Turn the water supply ON 6 Make sure there is power to the unit then place the ice machine control knob on the control shaft and turn the ice machine control knob to the...

Reviews: