Sub-Zero 315I Service Manual Download Page 3

Page 3

Model 315I (UC Ice Maker)

Installation Information

2-3

#3757320 - Revision B - August, 2005

ELECTRIC SHOCK HAZARD

Plug into grounded 3 prong outlet.

Do not remove ground prong from power cord.

Do not use a two prong adapter.

Do not use an extension cord.

Failure to follow these instructions can result in fire,
electrical shock or death.

Unit Dimensions

21 3/8"

15"

19 3/4"

115°

DOOR SWING

1/8"

1/8"

15"

1/8"

1/8"

33 7/8"

(minimum)

29 1/8"

Moving the Unit

When the unit is moved into the house, or if it needs to
be removed from the house for service purposes, it rec-
ommended to use a hand truck or dolly.  Be sure to
position the dolly on the side of the unit and securely
tape the door shut so it does not open while transport-
ing the unit.

Possible Need for Unit Removal

Although the model 315I has been designed to be serv-
iced in place, in some cases it may be necessary to pull
the unit out for service.  For that reason, the area under
the ice maker must be at the same level as the sur-
rounding finished floor and any decorative molding at
top or bottom must be removable.  Also, there must be
a minimum of 1/8” clearance on each side of the unit.

To avoid damage to the finished floor when the unit
is installed, or if the unit needs to be removed for
service purposes, the finished floor should be pro-
tected with appropriate material.

Drain

There are two 315I models with different drainage con-
figurations, the 

model 315I

and 

model 315IP

:

The 

model 315I

is a gravity drain model that requires a

drain tube that is pitched down from the outlet at the
back of the cabinet directly to the sanitary sewer drain.

NOTE:

 

All horizontal runs of drain line must have a

1/4” per foot fall.  An air gap will likely be required
between the ice maker drain tube and the drain/waste
receptacle.  A stand pipe with a trap below it would be
acceptable for the drain/waste receptacle.

The

model 315IP

has a built-in drain pump that will

pump water up to a drain point (maximum 10’ rise).

NOTE:

 

Poor drainage with either model will cause a

high rate of ice melting in the ice bin.

NOTE:

 

All plumbing must meet local codes.

Electricity

The model 315I is supplied with a three prong power
cord to be plugged into a grounded wall outlet.  

(See

Figure 2-2)

  The outlet should be on a branch circuit of

115 VAC, 60 Hz, single phase 15 amp, delayed action
fuse or circuit breaker.  The ice machine should be the
only device using that circuit.

Figure 2-2.  Power Cord & Wall Outlet

NOTE: 

This diagram

shows front view, side
view and top view of
the model 315.

Though the unit is 15”
wide, there must be a
minimum of 1/8”
clearance on each
side of the unit.  Be
sure to reference the
Pre-Installation
Specifications on the
following pages.

Summary of Contents for 315I

Page 1: ...Installation Information 6 subzero com 800 222 7820 315 Service Manual...

Page 2: ...s are chemically bonded to the water mole cules referred to as dissolved solids and cannot be fil tered out Ice made by the model 315I will have a lower mineral content than the water it is made from...

Page 3: ...service purposes the finished floor should be pro tected with appropriate material Drain There are two 315I models with different drainage con figurations the model 315I and model 315IP The model 315I...

Page 4: ...r line through back of compressor area to front of unit keeping tubing towards left side 4 Route drain tube from drain waste receptacle through back of compressor area to front of unit keeping tubing...

Page 5: ...outlet 7 Push ice maker into installation position 8 Cut inlet water line to required length NOTE It is recommended to flush the inlet water line at this time by turning water supply on and letting th...

Page 6: ...through hinge into mounting holes and tighten Then move top right hinge to bottom left hinge mounting holes and insert two hinge mounting screws through hinge into mounting holes and tight en 7 Attac...

Page 7: ...ce making sure to not damage front of panel 2 Position plastic drilling template provided with unit on back of door panel flush with upper edge and side of door panel See Figure 2 8 NOTE The size of t...

Page 8: ...eeding to the hinge cover installation instructions NOTES DO NOT attempt to install the hinge covers before the 90 door stop pins are installed if used If the 90 stop pins are installed it will be nec...

Page 9: ...h button out See Figure 2 13 5 Turn the water supply ON 6 Make sure there is power to the unit then place the ice machine control knob on the control shaft and turn the ice machine control knob to the...

Reviews: