Page 4
Installation Information
Model 315I (UC Ice Maker)
2-4
#3757320 - Revision B - August, 2005
INSTALLATION
Leveling (Model 315I & 315IP)
Note:
The unit must be leveled prior to installation.
There are four leveler legs on a model 315I, one at
each corner. To level the unit, turn the leveler legs
counterclockwise to raise the unit or clockwise to lower
it.
UP
UP
UP
Figure 2-3. Unit Leveling
PRE-INSTALLATION SPECIFICATIONS
(Model 315I - Gravity Drain Model)
Installation Instructions
(Model 315I - Gravity Drain Model)
1.
Place ice maker in front of installation location.
Level unit as described above.
2.
Remove door with hinges, kickplate, lower stainless
steel face plate, control knob and control panel.
3.
Route inlet water line through back of compressor
area to front of unit, keeping tubing towards left
side.
4.
Route drain tube from drain/waste receptacle,
through back of compressor area to front of unit,
keeping tubing towards left side.
NOTE:
If using a long horizontal run (more than 5
feet), the drain should be vented at back of unit.
5.
Plug power cord into wall outlet.
6.
Push ice maker into installation position.
7.
Cut inlet water line to required length.
NOTE:
It is recommended to flush the inlet water line
at this time by turning water supply on and letting the
water drain into a bucket.
8.
Place flare nut onto inlet water line, then flare end
of tube.
9.
Attach flare nut to water valve inlet.
10. Cut drain tube to required length.
11. Connect drain tube to bin drain fitting and secure it
with a hose clamp.
12. Turn water supply on and check for leaks.
13. Replace all parts removed in step 2.
NOTE:
All
plumbing
must meet
local
codes.