ionTig 200 AC/DC
Copyright © Mundaka Welding & Gases, Inc.
19
Unit Hz
Setting range 50—250 (Iw<50A)
50—200 (50A≤Iw<100A)
50—150 (100A≤Iw<150A)
50—100 (150A≤Iw<200A)
Balance (only with TIG-AC)
Balance adjustment is mainly used to set the adjustment of eliminating metal-oxide (such as Aluminum,
Magnesium and its alloy) while AC output.
Unit %
Setting range 15—50
Factory setting 15
(9) Rod electrode (MMA) welding key
Parameter Setting range
Arc force
0-10
Hot start
0-10
Arc length
0-10
(10) Power/Alarm indicator
Light up if the power switch on
Light up if the welder overheat, over-voltage or over-current. At the same time,
display Err 001.
(11) Welding voltage/other parameter display
Indicate the welding voltage or other parameter.
Before the start of welding, the right-hand display shows the pre-set value of Tpr, Tup, Dcy, Fp, Tdown
andTpo. There is a 3s time-lag, open-circuit voltage is displayed after adjusting those parameters.
After the start of welding, the right-hand display shows the present actual value of the welding voltage.
(12) Welding current display
Display the pre-set or the actual welding current value.
Before the start of welding, the left-hand display shows the pre-set current value of Is, Iw, Ib and Ic.