Available parameters where 2T and 4T mode have been selected:
Tpr Gas pre-flow time
Unit S
Setting range 0.1—1
Factory setting 0.3
Is Starting current (only with 4T)
Unit A
Setting range 5—100%of main current Iw (DC)
;
10—100%of main current Iw (AC-HF)
30—100%of main current Iw (AC-LIFT)
Factory setting 5
Tup
Upslope time
Unit S
Setting range 0—10
Factory setting 0
Iw Welding current
Unit A
WSME-160 5—160 (TIG-DC)
;
10—160 (TIG-AC-HF)
;
30—160 (TIG-AC-LIFT)
;
WSME-200 5—200 (TIG-DC)
;
10—200 (TIG-AC-HF)
;
30—200 (TIG-AC-LIFT)
;
5—170 (MMA-DC)
;
10—170 (MMA-AC)
Tpr
Is
Tup
Iw
Ic
Tpo
Tdown
Fp
Dcy
Ib
Iw