For extended storage in moderate climates,
the batteries must
be
charged for 8 hours every 2 months
by plugging the
power cord into the wall receptacle. Repeat it every month in high
temperature locations.
2.3 Storage Instructions
Press the front power switch again for few seconds, the UPS will
turn OFF the power to equipment (O/P OFF) . if the AC Power
Cord is still connected, LED will blink in green color indicating that
the battery is charging. To turn OFF the power completely,
please pull out the power Cord
.
To test backup function during power failure, press the front
power switch for few seconds. The UPS will work in backup mode
with buzzer beeps. In this mode the LED glows continuously in
Red color. To turn OFF the UPS, Please press the front Power
Switch again for few seconds.
The UPS will automatically turn OFF the output power during
backup mode when power consumption is lower than 6% of full
specified load.
If overload condition occurs, the buzzer will beep rapidly. The
LED will also blink rapidly in red color indicating the condition of
overload. Please proceed to
unplug the least critical equipment.
In
case of low battery, the LED will blink slowly.
Storage
Instructions