2
®
CyberPack
Air Filtration
CyberPack systems include high effi ciency, disposable
fi lters which are easily accessed through a hinged access
door on the front of the cabinet. MERV 8 fi lters are
provided as standard. Optional MERV 11 or MERV 14 rated
fi lters, offering higher levels of air fi ltration, are available.
Dual Refrigeration Circuits
CyberPack systems incorporate scroll compressor
technology. Dual compressors are staged for highly energy
effi cient system operation.
The refrigerant circuits include
fl ooded head pressure control and a receiver is provided
for each circuit. Evaporator coils are equipped with a
stainless steel condensate pan which drains outside of
the cabinet.
No refrigerant piping in the fi eld is required. CyberPack
systems are piped, fully charged and tested at the factory
before shipment.
Scroll Compressors
Highly reliable scroll compressors are utilized in CyberPack
systems. With fewer moving parts, scroll compressors
have demonstrated superior durability. Scroll compressors
provide higher effi ciency, higher reliability and quieter
operation than other compressor technologies.
Air Cooled Condensers
The integrally mounted air cooled condensers are
high efficiency state-of-the-art condensers utilizing
microchannel coils for greater total heat rejection. A
condensing unit for each refrigeration circuit is located
at the end of the cabinet. Microchannel coils in the
condensing units are all-aluminum construction with
microchannel fi ns.
The condensing units are equipped with high effi ciency
EC axial fans. The fans utilize corrosion resistant, multi-
blade impellers designed for high aerodynamic effi ciency,
which results in lower power consumption, lower noise
levels and longer life.
Microchannel Condenser Coils
Microchannel coils are constructed of brazed aluminum
high performance fi ns to provide low air-side pressure
drop and high heat transfer. Microchannel condenser coils
provide the same heat rejection as standard condenser coils,
but with a smaller footprint and require less refrigerant.
In general, Microchannel air cooled condensers provide
the same heat rejection as a standard condenser, but
with up to:
• 20% less refrigerant
• 40% smaller footprint
• 50% lighter weight
Header
Parallel Flow
Tubes
Enhanced
Aluminum
Fins
Microchannel Design
Microprocessor Control
CyberPack systems utilize the highly versatile and fl exible
STULZ
E
2
series controls for precision temperature and/or
humidity control. Designed primarily for STULZ precision
air conditioners, STULZ
E
2
Controllers offer a wide range
of expanded control functions and alarms.
The STULZ
E
2
Controller features a “menu-driven”
operating environment to allow system setup and
operation via an easy to read user interface display panel
which is typically mounted inside the electrical enclosure.
Power Usage Meter (Optional)
A power meter is used to monitor real-time power
consumption data. A display screen may be called up
in the
E²
controller user interface to view the data. The
power consumption data may also be viewed via a BMS
interface to the controller.
Pr
oduct Design Featur
es and Options