![Studiomaster digiLiVE 16 User Manual Download Page 22](http://html1.mh-extra.com/html/studiomaster/digilive-16/digilive-16_user-manual_1387108022.webp)
22
Gain, Frequency and Q can be adjusted using the on-screen soft-encoder by selecting it
through touch and subsequently “dragging” it to point towards the desired value. The
selected soft-encoder can also be adjusted using the blue-lit main encoder on the front
panel. Pressing and holding down the main encoder allows for fine adjustment of the
selected parameter.
Gain:
each band can be adjusted between -18 dB and +18 dB. Default setting is 0 dB.
Frequency
: each band can be set to a value between 20 Hz and 20 kHz. Default values are:
HF 4kHz, HMF 1kHz, LMF 200 Hz, LF 60Hz. The terms HF, HMF, LMF and LF only refer to
the initial setting of the bands; there is no restriction in setting the EQ bands so after setup
LF may actually be at the top of the frequency range.
Q
: allows bandwidth adjustment from 0.5(wide) to 10.0(narrow). Default is 0.5.
⑦
Library
The library allows to save and load user EQ settings. Tap the dropdown button and select a
library entry from the list to load its settings. Tap the “Save” button and select the desired
library slot (1 – 16) from the list to save the current EQ settings. A soft keyboard will pop-up
on screen to enter a name for the setting. Finally hit “confirm” to save the setting or “cancel”
to abandon.