5&$)/*$"-'&"563&4$"3"55&3*45*$)&5&$/*$)&

t4063$&

  n. 30 Monochromatic White LEDs (5000K) 
  Total out lumen: 12.000lm
  Total light power: 90W

  On request:
  3000K, 4000K, 6000K white LEDs or red, green, blue, amber LEDs

t015*$

  25° medium (38 mm lenses)
  On request: narrow, wide (38 mm lenses)

t5*-5

  Manual 160° 

t$0//&$5*0/4

  Main Power: 3pin IP 67 connector (male-female), possibility to link up to 8 devices at 230V or 4 devices at 120V in chain.

t4"'&5:

  n. 2 eyebolts for safety chains

t4&561"/%$0/'*(63"5*0/

  Standard version is Plug-in 
  On request: dimmable version

t*13"5*/(1305&$5*0/
t108&34611-:

 

 Voltage range: 100-240VAC

  Frequency range: 47-63Hz
  Active Power factor:
  PF>0.94/230VAC, PF>0.98/120VAC
  Current: 0.60A@230VAC
  Power: 100W
  Fuse T4A (inside fixture)

t1):4*$"-

  WxDxH: 928 x110x93 mm (dimension of profile)
  Weight: 6 Kg.

W

W

B

G

R

W

warm neutral cool

A

* 90cm - 30 LEDs

60cm - 20 LEDs

120cm - 40 LEDs

150cm - 50 LEDs

ITEM

FIXTURE

90cm standard

60cm

120cm

150cm

LEDs

Monochromatic 

30 warm, neutral, cool

20 warm, neutral, cool

40 warm, neutral, cool

50 warm, neutral, cool

On request: red, green, blue or amber

LEDs

White Balance

15 (2900K) + 15 (6000K)

10 (2900K) + 10 (6000K)

20 (2900K) + 20 (6000K)

25 (2900K) + 25 (6000K)

Total light power

90W

60W

120W

150W

Lumen

12000

8000

16000

20000

Optics

medium beam (38 mm lenses)  -  On request: narrow, wide or 20°x30° beam

Power consumption

100W

67W

135W

168W

Voltage range

Universal 100 - 240Vac

Physical

925x110x93 mm (profile dim.)  632x110x93 mm (profile dim.)

1222x110x93 mm (profile dim.) 1517x110x93 mm (profile dim.)

Weight

6 Kg

-

-

-

Summary of Contents for ARCHIBAR SL200

Page 1: ...User manual for art 15181 15182 Manuale d uso per art 15181 15182 monochromatic white balance...

Page 2: ...F The cable is not endowed with the connectors kit Se volete utilizzare gli apparecchi all ESTERNO potete realizzare dei nuovi cavi con art 4 PIN CONN M F Il cavo non incluso nel kit dei connettori a...

Page 3: ...nection Collegamento segnale DMX Page 9 Rear view xture connections Vista posteriore connessioni apparecchio Page 10 Control panel functions Menu Funzioni del pannello di controllo Menu Page 14 DMX Li...

Page 4: ...TFSWJ JP LEGGERE ATTENTAMENTE TUTTI GLI AVVERTIMENTI PRIMA DI COMPIERE QUALUNQUE OPERAZIONE SU QUESTO APPARECCHIO ISTRUZIONI PER PREVENIRE LESIONI O DANNI DOVUTI AL FUOCO ALLE SCOSSE ELETTRICHE AI RI...

Page 5: ...Z 0OMZ UIF DPOTJHOFF QFSTPO PS DPNQBOZ DBO DMBJN GPS UIFTF EBNBHFT 530 6 0 Vi ringraziamo per l utilizzo del nostro Archibar SL200 Monocromatico L Archibar SL200 M o WB ha lo stesso design dell Archib...

Page 6: ...94 230VAC PF 0 98 120VAC Current 0 60A 230VAC Power 100W Fuse T4A inside xture t 1 4 WxDxH 928 x110x93 mm dimension of pro le Weight 6 Kg W W B G R W warm neutral cool A 90cm 30 LEDs 60cm 20 LEDs 120...

Page 7: ...GL OLQHD Example 2 Esempio 2 DMX DVW WXUH 8OWLPR IDUR 7HUPLQDWLRQ UHVLVWRU 7HUPLQDOH GL OLQHD OLQH OLQHD 7HUPLQDWLRQ UHVLVWRU 7HUPLQDOH GL OLQHD OLQH OLQHD 0 RXW 0 RXW RQQHFWLRQ FRQWUROOHU VSRW WR 0...

Page 8: ...rado di protezione IP67 in caso di sostituzione del cavo di alimentazione fare riferimento alla TABELLA SEZIONE CONDUTTORE eng ita WARNING 70 5 MXBZT EJTDPOOFDU UIF NBJOT TVQQMZ CFGPSF BDDFTT UP UIF D...

Page 9: ...della linea La resistenza terminale dovrebbe avere idealmente lo stesso valore dell impedenza del cavo di collegamento Noi consigliamo di usare come terminale una resistenza da 120 Ohm E raccomandato...

Page 10: ...nce ESC DOWN UP ENTER 1 2 3 4 DMX led If you want to enter into setup mode you must follow the start procedure Se desiderate entrare nella modalit setup dovete seguire la procedura di accesso Press ke...

Page 11: ...ottomenu NFOV EESFTT EES 4FU UIF 9 BEESFTT NQPTUB M JOEJSJ P 9 press ENTER premere ENTER Select the channel number D D whit the UP DOWN buttons Press ENTER Selezionate il canale desidarato D D con i t...

Page 12: ...e a personal scene you can create a custom color utilizing the menu which will appear below RED GREEN BLUE WHITE WHITE BALANCE varying the DMX values from 0 to 255 for each color Se il menu SCENE ScnE...

Page 13: ...T GVODUJPOT VO JPOJ XJSFMFTT press ENTER for submenu premere ENTER per i sottomenu O C OBCMF XJSFMFTT Enable or disable the wireless reception Consente o non consente la ricezione wireless The cable r...

Page 14: ...the xture Imposta il numero di canali DMX dell apparecchio Select the value 9 5 4 with the UP DOWN buttons Press ENTER see DMX channel page Selezionate il valore desidarato 9 5 4 con i tasti UP DOWN P...

Page 15: ...z 128 255 CH4 LED FADE TIME FAST 0 1 sec 0 CUT SLOW 25 5 sec LINEAR 8 BIT FUNCTION 0 31 63 95 127 159 191 233 255 CH1 BALANCED WHITE 0 15 NORMAL 16 255 WW CW 015 0 0 5 0 50 9 0 44 0 01 0 9 9 MJOF GPS...

Page 16: ...to da Approvato da Data 1 1 Edizione Foglio Data 925 00 490 00 114 06 base fixing dimensions are good for ARCHIBAR SL300 rgbw and monochromatic 600mm and 900mm length ARCHIBAR SL200 rgbw and monochrom...

Page 17: ...irement of Directives LV 73 23 AND 93 68 EEC EMC 89 336 AND 93 68 EEC VITERBO 16 11 2015 15 Data di apposizione Date of marking Doc 15181 REV 1 11 15 ARCHIBAR SL200 MONOCHROMATIC 11 15 EN 60598 1 Ed V...

Page 18: ...irement of Directives LV 73 23 AND 93 68 EEC EMC 89 336 AND 93 68 EEC VITERBO 16 11 2015 15 Data di apposizione Date of marking Doc 15182 REV 2 11 15 ARCHIBAR SL200 WHITE BALANCE 11 15 EN 60598 1 Ed V...

Page 19: ...osto di imballaggio del 2 sul prezzo netto per tutti gli articoli Detti prezzi possono essere soggetti a possibili variazioni per eventuali aumenti dei costi di produzione o imposte La merce viaggia a...

Page 20: ...sono essere soggette a variazioni senza preavviso FBE 0GmDF 456 0 6 T S M Str Poggino 100 01100 Viterbo Italy tel 39 0761 352520 fax 39 0761 352653 info studiodue com XXX TUVEJPEVF DPN for technical i...

Reviews: