background image

4

rel.1 - 09/17  -  Studio Due

eng

WARNING

!

SAFETY INFORMATION (service personnel)

READ ALL CAUTIONS AND WARNINGS PRIOR TO OPERATE THIS EQUIPMENT.

INSTRUCTION TO PREVENT INJURY OR DAMAGE DUE TO ELECTRIC SHOCK, FIRE, MECHANICAL HAZARDS,

DANGEROUS MATTERS.

t1305&$5*0/"("*/45'*3&

1) Maintain minimum distance of 0.1 meter from walls or any other type flammable surfaces.
2) Maintain minimum distance of 0,1 meter to lighted objects .
3) Replace fuses (if present) only with the specified type and rating.
4) Do not install the fixture close to heat sources. Do not lay the connection cable on the fixture when it is warm.
5) Fixture designed to be installed on normally flammable surfaces.

t1305&$5*0/"("*/45&-&$53*$4)0$,

1) 

This equipment must be earthed.

2) Class I equipment. The power supply cord includes a protective earthing conductor as part of the cord.
3) Disconnect power before servicing (service personnel).

t1305&$5*0/"("*/45.&$)"/*$"-)";"3%4

1) Use secondary safety chain when fixing this equipment.
2) Equipment surface may reach temperature up to 75°C. 
3) The protection screens and the lenses must be replaced with genuine parts only if they are visibly damaged and 
    their effectiveness has been reduced, for example, by cracks or deep scratches.

t1305&$5*0/"("*/45%"/(&3064."55&34

At the end of its life, must be collected separately. It shouldn’t be thrown as urban waste and neither released in the 
environment.
It must be collected from the nearest special waste collection point or consigned to your dealer that provides the servi-
ce. The incorrect waste disposal can damage the environment and the people for the presence of dangerous substan-
ces. Sanctions are  provided for an unauthorized disposal.

F

*/'03.";*0/*%*4*$63&;;" QFSTPOBMFEJTFSWJ[JP

LEGGERE ATTENTAMENTE TUTTI GLI AVVERTIMENTI PRIMA DI COMPIERE QUALUNQUE OPERAZIONE SU QUESTO

APPARECCHIO. ISTRUZIONI PER PREVENIRE LESIONI O DANNI DOVUTI AL FUOCO, ALLE SCOSSE ELETTRICHE,

 AI RISCHI MECCANICI ED A SOSTANZE PERICOLOSE.

t1305&;*0/&$0/530*-'60$0

1) Mantenere la distanza minima di 0.1 metri da pareti ed altre superfici infiammabili.
2) Mantenere la distanza minima di 0,1 metri dagli oggetti illuminati.
3) Sostituire i fusibili (se presenti) solo con altri dello stesso tipo e valore.
4) Non installare il faro vicino fonti di calore. Non appoggiare il cavo di connessione sul faro quando questo è caldo.
5) Questo apparecchio è adatto per il montaggio su superfici normalmente infiammabili. 

t1305&;*0/&$0/5304$044&&-&553*$)&

1) 

Questo apparecchio necessita di messa a terra.

2) Apparecchio di Classe I. Il conduttore di protezione deve far parte del cavo di alimentazione.
3) Disconnettere l’alimentazione prima di aprire l’apparecchio (personale di servizio).

t1305&;*0/&$0/5303*4$)*.&$$"/*$*

1) Usare la catena di sicurezza supplementare quando installate il faro.
2) La temperatura dell’apparecchio può raggiungere 75°C.
3) Gli schermi di protezione e le lenti devono essere sostituiti sempre con ricambi originali 
   se sono visibilmente danneggiati e se la loro efficacia è stata ridotta, per esempio, da fessure o incisioni profonde.

*.1035"/5&

!

t1305&;*0/&$0/5304045"/;&1&3*$0-04&

A fine vita è oggetto di raccolta separata, non gettare nei comuni cassonetti di rifiuti urbani, né tantomeno nell’am-
biente. Può essere consegnato presso gli appositi centri di raccolta differenziata predisposti dalle amministrazioni 
comunali, oppure presso i rivenditori che forniscono questo servizio. Lo smaltimento errato può causare danni alle 
persone e all’ambiente per la possibile presenza di sostanze pericolose. Sono previste sanzioni in caso di smaltimen-
to abusivo dei suddetti prodotti.

F

0,1 m

ita

0,1 m

IP67

IP67

Summary of Contents for ARCHIBAR SL200

Page 1: ...User manual for art 15181 15182 Manuale d uso per art 15181 15182 monochromatic white balance...

Page 2: ...F The cable is not endowed with the connectors kit Se volete utilizzare gli apparecchi all ESTERNO potete realizzare dei nuovi cavi con art 4 PIN CONN M F Il cavo non incluso nel kit dei connettori a...

Page 3: ...nection Collegamento segnale DMX Page 9 Rear view xture connections Vista posteriore connessioni apparecchio Page 10 Control panel functions Menu Funzioni del pannello di controllo Menu Page 14 DMX Li...

Page 4: ...TFSWJ JP LEGGERE ATTENTAMENTE TUTTI GLI AVVERTIMENTI PRIMA DI COMPIERE QUALUNQUE OPERAZIONE SU QUESTO APPARECCHIO ISTRUZIONI PER PREVENIRE LESIONI O DANNI DOVUTI AL FUOCO ALLE SCOSSE ELETTRICHE AI RI...

Page 5: ...Z 0OMZ UIF DPOTJHOFF QFSTPO PS DPNQBOZ DBO DMBJN GPS UIFTF EBNBHFT 530 6 0 Vi ringraziamo per l utilizzo del nostro Archibar SL200 Monocromatico L Archibar SL200 M o WB ha lo stesso design dell Archib...

Page 6: ...94 230VAC PF 0 98 120VAC Current 0 60A 230VAC Power 100W Fuse T4A inside xture t 1 4 WxDxH 928 x110x93 mm dimension of pro le Weight 6 Kg W W B G R W warm neutral cool A 90cm 30 LEDs 60cm 20 LEDs 120...

Page 7: ...GL OLQHD Example 2 Esempio 2 DMX DVW WXUH 8OWLPR IDUR 7HUPLQDWLRQ UHVLVWRU 7HUPLQDOH GL OLQHD OLQH OLQHD 7HUPLQDWLRQ UHVLVWRU 7HUPLQDOH GL OLQHD OLQH OLQHD 0 RXW 0 RXW RQQHFWLRQ FRQWUROOHU VSRW WR 0...

Page 8: ...rado di protezione IP67 in caso di sostituzione del cavo di alimentazione fare riferimento alla TABELLA SEZIONE CONDUTTORE eng ita WARNING 70 5 MXBZT EJTDPOOFDU UIF NBJOT TVQQMZ CFGPSF BDDFTT UP UIF D...

Page 9: ...della linea La resistenza terminale dovrebbe avere idealmente lo stesso valore dell impedenza del cavo di collegamento Noi consigliamo di usare come terminale una resistenza da 120 Ohm E raccomandato...

Page 10: ...nce ESC DOWN UP ENTER 1 2 3 4 DMX led If you want to enter into setup mode you must follow the start procedure Se desiderate entrare nella modalit setup dovete seguire la procedura di accesso Press ke...

Page 11: ...ottomenu NFOV EESFTT EES 4FU UIF 9 BEESFTT NQPTUB M JOEJSJ P 9 press ENTER premere ENTER Select the channel number D D whit the UP DOWN buttons Press ENTER Selezionate il canale desidarato D D con i t...

Page 12: ...e a personal scene you can create a custom color utilizing the menu which will appear below RED GREEN BLUE WHITE WHITE BALANCE varying the DMX values from 0 to 255 for each color Se il menu SCENE ScnE...

Page 13: ...T GVODUJPOT VO JPOJ XJSFMFTT press ENTER for submenu premere ENTER per i sottomenu O C OBCMF XJSFMFTT Enable or disable the wireless reception Consente o non consente la ricezione wireless The cable r...

Page 14: ...the xture Imposta il numero di canali DMX dell apparecchio Select the value 9 5 4 with the UP DOWN buttons Press ENTER see DMX channel page Selezionate il valore desidarato 9 5 4 con i tasti UP DOWN P...

Page 15: ...z 128 255 CH4 LED FADE TIME FAST 0 1 sec 0 CUT SLOW 25 5 sec LINEAR 8 BIT FUNCTION 0 31 63 95 127 159 191 233 255 CH1 BALANCED WHITE 0 15 NORMAL 16 255 WW CW 015 0 0 5 0 50 9 0 44 0 01 0 9 9 MJOF GPS...

Page 16: ...to da Approvato da Data 1 1 Edizione Foglio Data 925 00 490 00 114 06 base fixing dimensions are good for ARCHIBAR SL300 rgbw and monochromatic 600mm and 900mm length ARCHIBAR SL200 rgbw and monochrom...

Page 17: ...irement of Directives LV 73 23 AND 93 68 EEC EMC 89 336 AND 93 68 EEC VITERBO 16 11 2015 15 Data di apposizione Date of marking Doc 15181 REV 1 11 15 ARCHIBAR SL200 MONOCHROMATIC 11 15 EN 60598 1 Ed V...

Page 18: ...irement of Directives LV 73 23 AND 93 68 EEC EMC 89 336 AND 93 68 EEC VITERBO 16 11 2015 15 Data di apposizione Date of marking Doc 15182 REV 2 11 15 ARCHIBAR SL200 WHITE BALANCE 11 15 EN 60598 1 Ed V...

Page 19: ...osto di imballaggio del 2 sul prezzo netto per tutti gli articoli Detti prezzi possono essere soggetti a possibili variazioni per eventuali aumenti dei costi di produzione o imposte La merce viaggia a...

Page 20: ...sono essere soggette a variazioni senza preavviso FBE 0GmDF 456 0 6 T S M Str Poggino 100 01100 Viterbo Italy tel 39 0761 352520 fax 39 0761 352653 info studiodue com XXX TUVEJPEVF DPN for technical i...

Reviews: