![Studer RCC-02 User Manual Download Page 87](http://html.mh-extra.com/html/studer/rcc-02/rcc-02_user-manual_1386490087.webp)
Studer Innotec SA
RCC-02/-03
User manual
83
Level
User
ref.
Parameter
Unit
12
24
48
Modi.
val
Factory
Min
Max
Factory
Min
Max
Factory
Min
Max
Expert
5094
SCOM
Expert
5105
Test of the modem's GPRS signal level
-
-
-
-
-
-
-
-
-
Inst.
5119
Device identification (LEDs) with the SCOM address
0
0
831
0
0
831
0
0
831
Inst.
5095
SCOM watchdog enable
No/Yes
No
-
-
No
-
-
No
-
-
19.2
I
NVERTER PARAMETERS
Level
User
ref.
Parameter
Unit
12
24
48
Mod.
value
Factory
Min
Max
Factory
Min
Max
Factory Min
Max
Basic
1100
BASIC SETTINGS
Basic
1551
Basic parameters set by means of the
potentiomenter in the XTS
No/Yes
Yes
-
-
Yes
-
-
Yes
-
-
Basic
1107
Maximum current of AC source (Input limit)
Aac
32
2
50
32
2
50
32
2
50
Basic
1138
Battery charge current
Adc
60
0
200
60
0
200
60
0
200
Basic
1126
Smart-Boost allowed
Yes/No
Yes
-
-
Yes
-
-
Yes
-
-
Basic
1124
Inverter allowed
Yes/No
Yes
-
-
Yes
-
-
Yes
-
-
Basic
1552
Type of detection of the grid loss (AC-In)
Text
Tolerant
-
-
Tolerant
-
-
Tolerant
-
-
Basic
1187
Standby level
%
10
0
100
10
0
100
10
0
100
Basic
1395
Restore default settings
-
-
-
-
-
-
-
-
-
Inst.
1287
Restore factory settings
-
-
-
-
-
-
-
-
-
Expert
1137
BATTERY MANAGEMENT AND CYCLE
Expert
1125
Charger allowed
Yes/No
Yes
-
-
Yes
-
-
Yes
-
-
Basic
1138
Battery charge current
Adc
60
0
200
60
0
200
60
0
200
Expert
1139
Temperature compensation
mV/°C/cell
-3
-8
0
-3
-8
0
-3
-8
0
Expert
1568
Undervoltage
Expert
1108
Battery undervoltage level without load
Vdc
11.6
9.5
18
23.2
19
36
46.3
37.9
72
Expert
1531
Battery
undervoltage
dynamic
compensation
Expert
1191
Battery
undervoltage
dynamic
compensation
No/Yes
Yes
-
-
Yes
-
-
Yes
-
-
Expert
1532
Kind of dynamic compensation
Text
Automatic
-
-
Automatic
-
-
Automatic -
-
Expert
1109
Battery undervoltage level at full load
Vdc
10.5
9.5
18
21
19
36
42
37.9
72
Expert
1190
Battery undervoltage duration before turn off min
3
0
60
3
0
60
3
0
60
Expert
1110
Restart voltage after batteries undervoltage Vdc
12
9.5
18
24
19
36
48
37.9
72
Expert
1194
Battery adaptive low voltage (B.L.O)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1195
Max voltage for adaptive low voltage
Vdc
12.5
10.2
12.6
25
20.4
25.2
49.9
40.8
50.4
Expert
1307
Reset voltage for adaptive correction
Vdc
13.2
9.5
18
26.4
19
36
52.8
37.9
72