![Studer RCC-02 User Manual Download Page 56](http://html.mh-extra.com/html/studer/rcc-02/rcc-02_user-manual_1386490056.webp)
Studer Innotec SA
RCC-02/-03
52
User manual
14.8.13.1
Authorized periodic absorption {1173}
Allows you to authorize the periodic absorption phase.
14.8.13.2
Periodic absorption voltage {1174}
Allows you to fix the battery voltage for the periodic absorption phase.
14.8.13.3
Duration of reduced floating before periodic absorption {1175}
The periodic absorption phase begins after the reduced floating phase. This setting allows you to fix
the duration of the reduced floating phase which precedes the periodic absorption phase.
14.8.13.4
Duration of periodic absorption {1176}
This setting fixes the duration of the periodic absorption. Once this duration has elapsed, the battery
returns to the reduced floating phase.
14.9
I
NVERTER
{1186}
To set the different parameters of the function inverter, use this menu.
14.9.1
Authorized inverter {1124}
This configuration authorizes operation in inverter mode. If the inverter is deactivated, a voltage will
be present on the output terminals (AC-Out) only if a correct voltage is present at the input (AC-In)
and the transfer is not prohibited.
This function can be used for supplying non-critical consumers while ensuring that the
battery is not discharged even if the source is faulty.
Note, that if the Smart-Boost function is activated, it is possible to discharge the
battery even if the inverter function is locked.
Where there is lock on the inverter, charger or transfer
function, a small padlock is displayed on the
configuration display.
14.9.2
Output voltage {1286}
The output voltage can be adjusted using this configuration.
In certain fields of application – for example, when the energy source is limited (solar
or generator only) – it may be useful to reduce the output voltage of the inverter. This
generally leads to a resulting reduction in the energetic consumption without
significantly decreasing comfort. For example, a 100 W light bulb consumes around
100W to 220V and 15% more at 230V.