OnAir 3000 Digital Mixing Console
5-48 Operation
Date printed: 31.10.08
SW V3.0
FDR Start
Trigger Point
Please note that it is recommended to perform this calibration for all faders
at a time.
First, move all faders
not
to be calibrated to their –20 dB position (this posi-
tion is ignored during calibration).
Center the fader knobs to be calibrated between the –
∞
and the –60 markers.
This will be the point where the fader start output is triggered after calibra-
tion.
Touch the
FDR Start
button. To check, close the faders that just have been
calibrated; the corresponding fader bars on the screen should disappear.
If you intend to calibrate a next fader module, touch the
Fader Cal
menu
button again and select the desired fader module.
5.3.8.3 (Admin) Firmware Page
On this page, the version number of all software modules of the console is
displayed for reference. A module is selected using the rotary encoder just
below the
Firmware
field.
Note:
A complete set of firmware for all console modules is saved in the main screen
module’s memory. After having replaced a module by one that has been e.g.
in the spare parts stock for some time, its firmware might not be up-to-date
with the ones of the other console modules. Therefore it is recommended to
check whether the firmware versions correspond. If not, the current version
may be downloaded from the main screen module to the module using the
Update Firmware
function.
Update Firmware
Select a module as described above; should its firmware be outdated, the
Update Firmware
button appears at the right of the list. The module’s
firmware will be updated when touching the
Update Firmware
button.
Summary of Contents for OnAir 3000
Page 1: ...Studer OnAir 3000 Digital Mixing Console SW Version 3 0 Operating Instructions ...
Page 16: ...Date printed 18 01 08 SW V2 0 OnAir 3000 Digital Mixing Console Important ...
Page 30: ...OnAir 3000 Digital Mixing Console 1 8 Introduction Date printed 31 10 08 SW V3 0 ...
Page 40: ...OnAir 3000 Digital Mixing Console 3 6 Operating Concept Date printed 31 10 08 SW V3 0 ...
Page 168: ...OnAir 3000 Digital Mixing Console 5 116 Operation Date printed 31 10 08 SW V3 0 ...
Page 274: ...OnAir 3000 Digital Mixing Console 7 14 A B Desk Configuration Date printed 31 10 08 SW V3 0 ...
Page 287: ...Studer D21m I O System Components Product Information March 2009 13th Edition ...