background image

Studer Innotec SA

BSP 

 

User manual 

V1.3 

9  

2

 

EU DECLARATION OF CONFORMITY 

The Battery Status Processor (BSP) described in this manual meets the requirements specified in 
the following EC directives and norms: 

Low voltage directive (LVD) 2014/35/EU 
- EN 62368-1:2014 

Electromagnetic Compliance (EMC) Directive 2014/30/EU 
- EN 61000-6-2:2005 - EN 61000-6-4:2007/A1:2011 

 

 

Studer Innotec SA contact details 

Studer Innotec SA 
Rue des Casernes 57 
CH - 1950 Sion 
Switzerland 
 
+41(0) 27 205 60 80 
+41(0) 27 205 60 88 
 
[email protected] 
www.studer-innotec.com 
 

 

Summary of Contents for BSP

Page 1: ...Studer Innotec SA 2017 V1 3 4O9H Battery Status Processor BSP User Manual ...

Page 2: ...www studer innotec com en downloads LEGAL NOTICE The use of Studer Innotec SA devices is the responsibility of the customer in all cases Studer Innotec SA reserves the right to make any modification to the product without prior notice PRODUCT RECYCLING The BSP conforms to the European directive 2011 65 EU on hazardous substances and does not contain the following elements lead cadmium mercury hexa...

Page 3: ...the communication bus 11 3 5 Signalisation LED 12 4 QUICK START GUIDE 13 4 1 Choosing the battery capacity 13 4 2 Choosing the shunt 13 4 3 Reset the battery history to zero 14 5 DISPLAY OF THE STATE OF THE BATTERY 14 5 1 Graph of the state of charge history 14 5 2 Values to display 14 6 SETTING OF THE PARAMETERS 16 6 1 Generalities 16 6 2 Levels of use and of accessibility 16 6 3 Basic settings 6...

Page 4: ...rcuit voltage 6044 18 6 4 10 Battery current limitation activated 6058 18 6 4 11 Max battery charge current 6059 18 6 4 12 Self discharge rate 6019 18 6 4 13 Nominal temperature 6020 19 6 4 14 Temperature coefficient 6021 19 6 4 15 Charge efficiency factor 6022 19 6 4 16 Peukert s exponent 6023 19 6 4 17 Use C20 capacity as reference value 6049 19 6 5 Configuration as simple counter 19 7 FACTORY S...

Page 5: ...instance that of a petrol gauge The different values that affect a battery are described below 1 1 1 Definition of battery capacity A battery s capacity is defined as the amount of electrical charge that a full battery can supply at given current before reaching a certain voltage Normally the unit Ampere hour Ah is used for its measurement An ideal 100 Ah battery should for instance supply 10 Ampe...

Page 6: ...y 1 25 Cref and Iref refer to the given capacity at a known current Discharge speed Capacity at C10 100 Ah at 10 A during 10 hours C3 0 74 C20 1 19 C50 1 50 C100 1 78 Capacity ratio with a Peukert exponent of 1 25 1 1 5 Capacity and battery lifetime The capacity decreases along the charge discharge cycles The deep discharges have a particularly negative impact High ambient temperatures lower also ...

Page 7: ... SA Nuts or screws partially or insufficiently tight during installation or maintenance Damages due to atmospheric overvoltage lightning Damages due to transport or improper packaging Disappearing of original marking items 1 3 2 Disclaimer of liability Installation commissioning use and maintenance of this device cannot be supervised by the company Studer Innotec SA For this reason we do not accep...

Page 8: ...to do any change modification or repair whatsoever Regarding authorized modifications and replacements only genuine components shall be used This device is meant for a use only indoor and must under no circumstances stand in the rain the snow or any other humid or dusty environment In case of use in motor vehicles this device must also be protected against vibrations by absorbing components 1 4 3 ...

Page 9: ... the following EC directives and norms Low voltage directive LVD 2014 35 EU EN 62368 1 2014 Electromagnetic Compliance EMC Directive 2014 30 EU EN 61000 6 2 2005 EN 61000 6 4 2007 A1 2011 Studer Innotec SA contact details Studer Innotec SA Rue des Casernes 57 CH 1950 Sion Switzerland 41 0 27 205 60 80 41 0 27 205 60 88 info studer innotec com www studer innotec com ...

Page 10: ... sensor BTS that will be connected to the Xtender In that case the temperature of the BTS will be automatically taken into account for the state of charge calculation Figure 3 1 Connecting schematic of the BSP 3 1 MOUNTING Ideally the BSP can be stuck directly to the battery It can also be mounted close to the battery by means of the fixing plate supplied with see figure 3 2 p 12 The direct mounti...

Page 11: ...ect the negative cables of the inverter the solar regulator and or DC consumers to the free bolt of the shunt The positive cables are being connected straight to the positive terminal of the battery e 6 Connect the communication cable to the communication bus of the Xtender system and activate if necessary the link end f For more information see the section 3 4 3 4 CONNECTING THE COMMUNICATION BUS...

Page 12: ...r When the BSP is connected with the communication bus to other devices Xtender VarioTrack RCC Xcom or other the software versions may not be compatible It is highly recommended to make a software update of all components in the system in order to guarantee all functionalities Therefore before starting the setup of the device download the latest software version from our website www studer innotec...

Page 13: ... DOWN to the general menu Then push on SET to enter the menu With the arrow DOWN move to the parameter Battery Capacity To modify its value push on SET The value turns in reverse video Change the value for the one of your battery with the keys UP and DOWN Confirm by pushing on SET Then configure the parameter Nominal Discharge Time C rating 6002 the same way as for the battery capacity 4 2 CHOOSIN...

Page 14: ... selection mode with the key SET The battery is then selected The key SET allows then to display the graph The graph of the state of charge is then displayed On the horizontal scale are today and the last 4 days The graduations indicate every hour from midnight to midnight Each horizontal pixel means one hour The vertical axis gives the state of charge of the battery The graduations mean 20 40 60 ...

Page 15: ...he BTS is connected or if not present Ah charged today Ah Charge supplied to the battery from midnight until now Ah discharged today Ah Charge supplied by the battery from midnight until now Ah charged yesterday Ah Ah discharged yesterday Ah Total kAh charged kAh Charge supplied to the battery from the last reset to zero of the battery history See Reset of battery history 6003 p 17 Total kAh disch...

Page 16: ...an automatic battery recognition mode When connected to a battery it will measure the available voltage and detect if it is a 12 V 24 V or 48V battery It is possible to force the BSP to function with a given voltage with parameter 6057 When the battery voltage is known it may be wise to set the battery voltage 12 V 24 V or 48 V This in order to avoid any confusion when connecting a highly discharg...

Page 17: ...nstaller 6 4 ADVANCED SETTINGS 6016 Parameters used for advanced configuration of the BSP 6 4 1 Reset of user counters 6031 This parameter allows to reset to zero the charge discharge and time user counters of the section 5 2 6 4 2 Manufacturer SOC for 0 displayed 6055 6 4 3 Manufacturer SOC for 100 displayed 6056 The capacity given by the battery manufacturer conforms to a discharge test that is ...

Page 18: ...th parameter 6024 can be corrected with this coefficient By using a reference temperature of 25 C it is possible to have a similar charge behaviour of the Xtender the VarioTrack or the VarioString 6 4 9 Activate the state of charge correction by the open circuit voltage 6044 When this parameter is activated the state of charge is corrected by the battery voltage This function is only effective for...

Page 19: ...n this parameter is set to no the capacity of parameter 6001 is used 6 5 CONFIGURATION AS SIMPLE COUNTER When using other battery technologies than lead it is necessary to configure the BSP as a simple counter without correction It is necessary to activate the end of charge synchronisation to avoid the state of charge to derive due to measuring errors and loss of battery capacity The parameters ca...

Page 20: ...ge level 13 2 26 4 52 8 V Expert 6025 End of charge current level 2 cap Expert 6065 Minimum duration before end of charge 5 minutes Expert 6031 Reset of user counters Expert 6042 Activate the end of charge synchronization No Expert 6044 Activate the state of charge correction by the open circuit voltage Yes Expert 6048 Temperature correction of the end of charge voltage 0 mV C cell Expert 6049 Use...

Page 21: ...A BSP 1200 Voltage measurement accuracy 0 3 Current measurement accuracy 0 5 Battery capacity 20 20000 Ah Operating temperature range 20 55 C Packed weight 900 g BSP 500 1500 g BSP 1200 Displayable values see table 6 1 Protection degree IP20 Conformity LVD 2014 35 EU EN 62368 1 2014 EMC 2014 30 EU EN 61000 6 2 2005 EN 61000 6 4 2007 A1 2011 RoHS 2011 65 EU 9 2 READOUT RESOLUTIONS Voltage 0 01 V Cu...

Page 22: ...Studer Innotec SA BSP 22 V1 3 User manual 9 3 DIMENSIONS ...

Page 23: ...Studer Innotec SA BSP User manual V1 3 23 9 4 MOUNTING ...

Page 24: ...Studer Innotec SA Rue des Casernes 57 CH 1950 Sion Switzerland 41 0 27 205 60 80 41 0 27 205 60 88 info studer innotec com www studer innotec com ...

Reviews: