ARRANTY AND LIABILITY

 

During production and assembling, each BSP gets several controls and tests. They are carried out 
in full respect of fixed procedures. Each BSP is given a serial number allowing a perfect follow-up 
of  the  controls,  in  conformity  with  the  specific  data  of  every  device.  For  this  reason,  it  is  very 
important to never remove the descriptive sticker bearing the serial number. The production, the 
assembling  and  the  tests  of  each  BSP  are  entirely  carried  out  in  our  factory  in  Sion  (CH).  The 
warranty of this product depends on strictly following the instructions in this manual. The warranty 
period for the BSP is 5 years. 

1.3.1

 

Disclaimer of warranty 

No warranty will be applied for damages caused by handling, operation or actions that are not 
described  in  this  manual.  Damages  arisen  from  the  following  events  are  not  covered  by  the 
warranty: 

 

Overvoltage on the device (Applying a voltage higher than 85 Vdc). 

 

Reverse polarity while connecting the battery. 

 

Liquid in the device or oxidation due to condensation. 

 

Failures due to a fall or to a mechanical shock. 

 

Modifications made without the explicit authorization of Studer Innotec SA. 

 

Nuts or screws partially or insufficiently tight during installation or maintenance. 

 

Damages due to atmospheric overvoltage (lightning). 

 

Damages due to transport or improper packaging. 

 

Disappearing of original marking items. 

1.3.2

 

Disclaimer of liability 

Installation,  commissioning,  use  and  maintenance  of  this  device  cannot  be  supervised  by  the 
company Studer Innotec SA. For this reason, we do not accept any liability for damages, costs or 
losses generated either by an installation that is not conforming to the prescriptions, by a defective 
operation or by poor maintenance. The use of this device is under the responsibility of the end-
user. This device is neither designed nor guaranteed for the supply of life support applications or 
any other critical application with potential risks for human beings of for the environment. We shall 
assume  no  liability  for  patent  infringement  or  other  third  party  rights  involved  in  the  use  of  this 
device. 

1.4

 

S

AFETY PRECAUTIONS

 

1.4.1

 

Generalities 

Do read carefully all safety instructions before proceeding to the installation and commissioning 
of the device. Not respecting these instructions might constitute a lethal physical danger but can 
also damage the functionalities of the device. Therefore, do keep this manual close to the device. 

 

Strictly follow the local and national norms and regulations in force. This is valid for all 
installations. 

Summary of Contents for BSP

Page 1: ...Studer Innotec SA 2017 V1 3 4O9H Battery Status Processor BSP User Manual ...

Page 2: ...www studer innotec com en downloads LEGAL NOTICE The use of Studer Innotec SA devices is the responsibility of the customer in all cases Studer Innotec SA reserves the right to make any modification to the product without prior notice PRODUCT RECYCLING The BSP conforms to the European directive 2011 65 EU on hazardous substances and does not contain the following elements lead cadmium mercury hexa...

Page 3: ...the communication bus 11 3 5 Signalisation LED 12 4 QUICK START GUIDE 13 4 1 Choosing the battery capacity 13 4 2 Choosing the shunt 13 4 3 Reset the battery history to zero 14 5 DISPLAY OF THE STATE OF THE BATTERY 14 5 1 Graph of the state of charge history 14 5 2 Values to display 14 6 SETTING OF THE PARAMETERS 16 6 1 Generalities 16 6 2 Levels of use and of accessibility 16 6 3 Basic settings 6...

Page 4: ...rcuit voltage 6044 18 6 4 10 Battery current limitation activated 6058 18 6 4 11 Max battery charge current 6059 18 6 4 12 Self discharge rate 6019 18 6 4 13 Nominal temperature 6020 19 6 4 14 Temperature coefficient 6021 19 6 4 15 Charge efficiency factor 6022 19 6 4 16 Peukert s exponent 6023 19 6 4 17 Use C20 capacity as reference value 6049 19 6 5 Configuration as simple counter 19 7 FACTORY S...

Page 5: ...instance that of a petrol gauge The different values that affect a battery are described below 1 1 1 Definition of battery capacity A battery s capacity is defined as the amount of electrical charge that a full battery can supply at given current before reaching a certain voltage Normally the unit Ampere hour Ah is used for its measurement An ideal 100 Ah battery should for instance supply 10 Ampe...

Page 6: ...y 1 25 Cref and Iref refer to the given capacity at a known current Discharge speed Capacity at C10 100 Ah at 10 A during 10 hours C3 0 74 C20 1 19 C50 1 50 C100 1 78 Capacity ratio with a Peukert exponent of 1 25 1 1 5 Capacity and battery lifetime The capacity decreases along the charge discharge cycles The deep discharges have a particularly negative impact High ambient temperatures lower also ...

Page 7: ... SA Nuts or screws partially or insufficiently tight during installation or maintenance Damages due to atmospheric overvoltage lightning Damages due to transport or improper packaging Disappearing of original marking items 1 3 2 Disclaimer of liability Installation commissioning use and maintenance of this device cannot be supervised by the company Studer Innotec SA For this reason we do not accep...

Page 8: ...to do any change modification or repair whatsoever Regarding authorized modifications and replacements only genuine components shall be used This device is meant for a use only indoor and must under no circumstances stand in the rain the snow or any other humid or dusty environment In case of use in motor vehicles this device must also be protected against vibrations by absorbing components 1 4 3 ...

Page 9: ... the following EC directives and norms Low voltage directive LVD 2014 35 EU EN 62368 1 2014 Electromagnetic Compliance EMC Directive 2014 30 EU EN 61000 6 2 2005 EN 61000 6 4 2007 A1 2011 Studer Innotec SA contact details Studer Innotec SA Rue des Casernes 57 CH 1950 Sion Switzerland 41 0 27 205 60 80 41 0 27 205 60 88 info studer innotec com www studer innotec com ...

Page 10: ... sensor BTS that will be connected to the Xtender In that case the temperature of the BTS will be automatically taken into account for the state of charge calculation Figure 3 1 Connecting schematic of the BSP 3 1 MOUNTING Ideally the BSP can be stuck directly to the battery It can also be mounted close to the battery by means of the fixing plate supplied with see figure 3 2 p 12 The direct mounti...

Page 11: ...ect the negative cables of the inverter the solar regulator and or DC consumers to the free bolt of the shunt The positive cables are being connected straight to the positive terminal of the battery e 6 Connect the communication cable to the communication bus of the Xtender system and activate if necessary the link end f For more information see the section 3 4 3 4 CONNECTING THE COMMUNICATION BUS...

Page 12: ...r When the BSP is connected with the communication bus to other devices Xtender VarioTrack RCC Xcom or other the software versions may not be compatible It is highly recommended to make a software update of all components in the system in order to guarantee all functionalities Therefore before starting the setup of the device download the latest software version from our website www studer innotec...

Page 13: ... DOWN to the general menu Then push on SET to enter the menu With the arrow DOWN move to the parameter Battery Capacity To modify its value push on SET The value turns in reverse video Change the value for the one of your battery with the keys UP and DOWN Confirm by pushing on SET Then configure the parameter Nominal Discharge Time C rating 6002 the same way as for the battery capacity 4 2 CHOOSIN...

Page 14: ... selection mode with the key SET The battery is then selected The key SET allows then to display the graph The graph of the state of charge is then displayed On the horizontal scale are today and the last 4 days The graduations indicate every hour from midnight to midnight Each horizontal pixel means one hour The vertical axis gives the state of charge of the battery The graduations mean 20 40 60 ...

Page 15: ...he BTS is connected or if not present Ah charged today Ah Charge supplied to the battery from midnight until now Ah discharged today Ah Charge supplied by the battery from midnight until now Ah charged yesterday Ah Ah discharged yesterday Ah Total kAh charged kAh Charge supplied to the battery from the last reset to zero of the battery history See Reset of battery history 6003 p 17 Total kAh disch...

Page 16: ...an automatic battery recognition mode When connected to a battery it will measure the available voltage and detect if it is a 12 V 24 V or 48V battery It is possible to force the BSP to function with a given voltage with parameter 6057 When the battery voltage is known it may be wise to set the battery voltage 12 V 24 V or 48 V This in order to avoid any confusion when connecting a highly discharg...

Page 17: ...nstaller 6 4 ADVANCED SETTINGS 6016 Parameters used for advanced configuration of the BSP 6 4 1 Reset of user counters 6031 This parameter allows to reset to zero the charge discharge and time user counters of the section 5 2 6 4 2 Manufacturer SOC for 0 displayed 6055 6 4 3 Manufacturer SOC for 100 displayed 6056 The capacity given by the battery manufacturer conforms to a discharge test that is ...

Page 18: ...th parameter 6024 can be corrected with this coefficient By using a reference temperature of 25 C it is possible to have a similar charge behaviour of the Xtender the VarioTrack or the VarioString 6 4 9 Activate the state of charge correction by the open circuit voltage 6044 When this parameter is activated the state of charge is corrected by the battery voltage This function is only effective for...

Page 19: ...n this parameter is set to no the capacity of parameter 6001 is used 6 5 CONFIGURATION AS SIMPLE COUNTER When using other battery technologies than lead it is necessary to configure the BSP as a simple counter without correction It is necessary to activate the end of charge synchronisation to avoid the state of charge to derive due to measuring errors and loss of battery capacity The parameters ca...

Page 20: ...ge level 13 2 26 4 52 8 V Expert 6025 End of charge current level 2 cap Expert 6065 Minimum duration before end of charge 5 minutes Expert 6031 Reset of user counters Expert 6042 Activate the end of charge synchronization No Expert 6044 Activate the state of charge correction by the open circuit voltage Yes Expert 6048 Temperature correction of the end of charge voltage 0 mV C cell Expert 6049 Use...

Page 21: ...A BSP 1200 Voltage measurement accuracy 0 3 Current measurement accuracy 0 5 Battery capacity 20 20000 Ah Operating temperature range 20 55 C Packed weight 900 g BSP 500 1500 g BSP 1200 Displayable values see table 6 1 Protection degree IP20 Conformity LVD 2014 35 EU EN 62368 1 2014 EMC 2014 30 EU EN 61000 6 2 2005 EN 61000 6 4 2007 A1 2011 RoHS 2011 65 EU 9 2 READOUT RESOLUTIONS Voltage 0 01 V Cu...

Page 22: ...Studer Innotec SA BSP 22 V1 3 User manual 9 3 DIMENSIONS ...

Page 23: ...Studer Innotec SA BSP User manual V1 3 23 9 4 MOUNTING ...

Page 24: ...Studer Innotec SA Rue des Casernes 57 CH 1950 Sion Switzerland 41 0 27 205 60 80 41 0 27 205 60 88 info studer innotec com www studer innotec com ...