background image

Connecting the Welding Leads

 

1. Connect the stud gun weld cable into the gun terminal socket on the front of the welding unit. The

cable end plug has a flat which aligns with a dot on the panel mount socket. Secure the connector
into the panel mount socket, and then turn it clockwise until it locks into proper position. 

Failure

to properly make these connections could result in damage to the connectors.

2. Connect the weld gun control cable into the center socket connector. The control cable plug has a

large pin and a small pin that match the socket on the unit. Push the plug firmly into the socket
and twist clockwise to secure the plug into the correct position.

3. Connect the ground clamp into the ground terminal socket on the front of the unit, this connec-

tion is identical to step 1.

Connecting the Ground Clamp

 

1. Prior to securing the clamp, make certain that

the contact area is free of rust, paint, grease, or
any other impurities to ensure a good ground
connection.

2.

Attach the clamp of the welding ground lead to
the work piece.

3.

Most applications will require only one ground
clamp

, but certain applications will require an

additional dual clamp.

SETUP AND WELDING 

9

 

Stud Gun

 Weld 

Cable 

Connection

 

Ground 

Cable Connection

 

Stud Gun 

Control 

Cable 

Connection

 

WWW.STUDWELDPROD.COM 

800-252-1919

Summary of Contents for StudPro 2500XI

Page 1: ...OPERATOR S MANUAL STUDPRO SERIES Capacitor Discharge Stud Welder MODELS StudPro 2500XI StudPro 2500XIP StudPro 3125XI StudPro 3750XI WWW STUDWELDPROD COM 800 252 1919...

Page 2: ...Description Pages Warranty Information 1 Safety 2 Specifications and Features 3 Product Components 4 5 Screen Operation 6 8 Setup and Welding 9 11 CD Stud Gun Exploded View 12 WWW STUDWELDPROD COM 800...

Page 3: ...hearing Wear earplugs or oth er protective gear if applicable Fumes and gases expelled during welding can be health hazards Make sure welding is done in a well ventilated area Hot metal splatter can c...

Page 4: ...ating or poor input power Rigid internal construction minimizes the possibility of components coming loose during rough han dling or operation Hand tool has been ergonomically designed to reduce opera...

Page 5: ...P only on all other TW i models this connector is a secondary Weld Ground Connector 4 Stud Gun Control Cable Connector 5 Stud Gun Weld Cable Connector 6 ON OFF Switch 7 10A Fuse 8 Manufacturer Model N...

Page 6: ...tion Fan 2 ON OFF Switch 3 10A Fuse 4 AC Inline Filter Power Cord Socket 5 Capacitor Bank 6 Freewheeling Diodes 7 SCR Clamp 8 Discharge Resistor 9 Control Board PRODUCT COMPONENTS 4 3 1 2 5 9 8 7 6 5...

Page 7: ...ts Metric Stud Mode Contact Indicator Stud Preset Screen Voltage Preset Screen Charge Indicator Welding Voltage Stud Counter Voltage Adjustment Adjustment Voltage Presets Mode Selection Voltage Mode S...

Page 8: ...RESET tab located at the bottom of the screen The screen will then prompt the user for a confirmation to clear the stud counter To cancel the resetting of the stud counter simply press NO on the scre...

Page 9: ...e Limiter Activated Protects capacitor from overheating by limiting the user to a maximum average duty cycle This protec tion only activates when the set point of the welder is above 85V Below 85V the...

Page 10: ...t on the unit Push the plug firmly into the socket and twist clockwise to secure the plug into the correct position 3 Connect the ground clamp into the ground terminal socket on the front of the unit...

Page 11: ...ount the two legs and foot piece onto the stud gun The collet should be centered through the opening of the foot piece 3 Insert the stud to be welded into the collet 4 Adjust the leg and foot piece by...

Page 12: ...chieve the desired results 2 Welding is done by placing the stud into the collet and pressing the stud gun to the work piece 3 Hold the gun perpendicular to the work piece align the stud to the desire...

Page 13: ...CD GUN EXPLODED VIEW 12 WWW STUDWELDPROD COM 800 252 1919...

Page 14: ...8 CDB 037 10 MM CDB 010M SOYER COLLETS STUD DIA PART NO 6 CDBS 013 4 MM CDBS 004M 8 CDBS 015 10 CDBS 018 5 MM CDBS 005M 6 MM CDBS 006M 1 4 CDBS 025 5 16 CDBS 031 CAPACITOR DISCHARGE ACCESSORIES 3 8 D...

Page 15: ...TUD STOP LENGTH LENGTH PART NO 1 4 1 1 4 033 781 3 8 1 1 8 033 782 1 2 1 033 783 5 8 7 8 033 784 3 4 3 4 033 785 7 8 5 8 033 775 1 1 2 033 776 1 1 8 3 8 033 777 1 1 4 1 4 033 778 1 3 8 BUTTON STOP 1 8...

Page 16: ...015 100 10 X 1 4 CI 018 025 10 X 3 8 CI 018 037 10 X 1 2 CI 018 050 10 X 5 8 CI 018 062 10 X 3 4 CI 018 075 10X 1 CI 018 100 1 4 X 1 4 CI 025 025 1 4 X 3 8 CI 025 037 1 4 X 1 2 CI 025 050 1 4 X 5 8 CI...

Page 17: ...WWW STUDWELDPROD COM 800 252 1919 WWW STUDWELDPROD COM 800 252 1919...

Reviews: