Page 2: ...btu system suitable for flats apartments offices and other small dwellings STORAGE If this product is not to be installed immediately on receipt ensure that it is stored in a dry frost and vibration...

Page 3: ...ome into contact with any electrical device before the electrical supply is turned back on z z The Electrastream unit must be commissioned by a competant person failure to do so will invalidate the gu...

Page 4: ...removed from its packaging check for any damage prior to installation If any damage is found contact Altecnic Ltd within 24 hours of receipt Item Description Qty Item Description Qty Electrastream uni...

Page 5: ...ing cupboards and enclosed compartments Humidity may also present a problem within airing cupboards For servicing and cylinder replacement clearance is required all round the cylinder recommended 100...

Page 6: ...guarantee Higher water temperatures of 65 C and above can cause excessive scale The location and position of the water conditioner should be as per the manufacturer s recommendations 1 5 Check water p...

Page 7: ...ffs The valve must be set to suit the pressure of the system refer to the manufacturer s instructions 1 12 Room thermostat not supplied A standard room thermostat with no built in timers or functions...

Page 8: ...tor RCD MCB Cylinder TPR valve 6 bar Thermostatic mixing vlave Hot water outlet 22 mm connection Cold water supply 22 mm connection Combination valve including hot water PRV 6 bar Tundish Drain valve...

Page 9: ...outlets prior to the Electrastream connection Both of these connections are for 22 mm pipe 3 2 Heating system a The total output from the Electrastream for hot water and heating is 9 kW 240 V having...

Page 10: ...possible to and lower than the safety device with no more than 600 mm of pipe between the valve outlet and the tundish 3 5 The discharge pipe D2 The discharge pipe D2 from the tundish should Have a v...

Page 11: ...Contain a mechanical seal not incorporating a water trap which allows water into the branch pipe without allowing foul air from the drain to be ventilated through the tundish b Be a separate branch pi...

Page 12: ...ed for a straight length of 28 mm copper discharge pipe D2 from a G temperature relief valve is 18 m Subtract the resistance for 4 No 28 mm elbows at 1 0 m each 4 m Therefore the maximum permitted len...

Page 13: ...current and temperature rating for the requirements of the Electrastream as well as all other electrical requirements within the property It is advised to turn the switch off when hot water and heatin...

Page 14: ...d therefore only a mains cable not supplied is required to be installed through the cable gland located at the top of the RCD box This 3 core cable suitably sized is connected into the live neutral an...

Page 15: ...15 Cont Fig 10 Wiring diagram standard arrangement...

Page 16: ...system Grey vessel Maximum charge pressure 1 5 bar Maximum working temperature 90 C Maximum Working Pressure 3 bar Capacity 8 litres for maximum system expansion of 7 litres The vessel pre charged is...

Page 17: ...arth wiring has been installed correctly b Check tri core heater cover Electrastream controller cover and all other electrical covers are correctly fitted c Check tundish is positioned so that any spi...

Page 18: ...s failed see 5 17 HEAT 2 Indicates Eleement 2 is ON HEAT 2 Indicates heater element has failed see 5 17 HEAT 3 Indicates Eleement 3 is ON HEAT 3 Indicates heater element has failed see 5 17 VALVE Inid...

Page 19: ...19 Cont Fig 12 Electrastream control unit display settings For error displays see 8 1...

Page 20: ...within 2 of the set Target 65 C only one element will be on When the hot water is between 2 and 4 C below the set target then two elements will be on When the hot water within the cylinder is below 6...

Page 21: ...re within the cylinder becoming too high the TPR valve will vent The heating system has its own Pressure relief valve PRV and in the event of the pressure within the heating system becoming too high t...

Page 22: ...has to make special arrangements to the property s electrical supply to enable Electrastream to be used during both off peak and normal tariffs consult the installing electrician Boost can be used at...

Page 23: ...er functions 4 How to set room thermostat 5 The function of the Pressure Relief Valves and Combination valve and that over pressure will cause steam and scalding water to be emitted from the discharge...

Page 24: ...TPR valve and check that the water drains freely and safely to and from the tundish 10 Open combination PRV momentarily and close valve should shut off Repeat if valve sticks If valve will not shut o...

Page 25: ...ths this is done by pressing the RCD Test or T button this should switch the supply off Reset RCD to On after test If the RCD appears not to be working correctly contact your installer or a qualified...

Page 26: ...eat time t 60 o C 25 minutes 29 minutes Heat loss in 24 hrs 65 o C 0 97 kWh 1 06 kWh Heating System Expansion vessel size 8 litres Maximum system expansion 7 litres Expansion vessel pre charge pressur...

Page 27: ...setup Check timers and target temperature on Electrastream Control unit are set correctly Trip cut out Check over temperature cut out Reset system by switching heating and hot water OFF and allow for...

Page 28: ...hould not be run with all the radiators turned off unless there is a bypass valve in the system Check for air in the heating system Check that the cylinder temperature sensor has not been dislodged fr...

Page 29: ...water that complies with current at the time of installation EU standards and is not fed with water from a private source d The unit must not be modified in any way e Being subjected to excessive pres...