Stuart Turner 46601 Installation, Operation & Maintenance Instructions Manual Download Page 18

- 18 -

Cont ...

9  THE MONSOON EXTRA GUARANTEE

Congratulations on purchasing a Stuart Turner pump. 
We are confident this pump will provide many years of trouble free service as all our 
products are manufactured to the very highest standard. 
All Monsoon Extra pumps are guaranteed to be free from defects in materials or 
workmanship for 2 years from the date of purchase.  

EXTEND YOUR PUMP GUARANTEE

Register your pump details on-line now (within 30 days of date of purchase) and the 
standard 2 year guarantee will be extended 

FREE

 of charge for a further one year.  

www.stuart-turner.co.uk 

If you do not have on-line access or would like us to help you register your pump then 
simply call our 

‘PumpAssist’

 helpline on 

0844 98 000 97

.

Please note that to validate your extended warranty we will require the following 
information:  
 

1.  Full pump serial number (including last 3 digits) which can be found on the  

 

 

 

pump rating label and the back page of the installation instructions. 

 

2.  Your name/address/telephone/e-mail.  

 

3.  The date of installation.

Within the guarantee period we will repair, free of charge, any defects in the pump 
resulting from faults in material or workmanship, repairing or exchanging the whole unit 
as we may reasonably decide. 
Not covered by this guarantee: Damage arising from incorrect installation, improper 
use, unauthorised repair, normal wear and tear and defects which have a negligible 
effect on the value or operation of the pump. 

Reasonable evidence must be supplied that the product has been purchased within the 
guarantee term prior to the date of claim (such as proof of purchase or the pump serial 
number). 

This guarantee is in addition to your statutory rights as a consumer.  If you are in any 
doubt as to these rights, please contact your local Trading Standards Department. 

In the event of a claim please telephone 

‘PumpAssist’

 or return the pump with the 

accessories removed e.g  pipes etc. If you have any doubt about removing a pump, 
please consult a professional.

0844 98 000 97

Summary of Contents for 46601

Page 1: ...it contains important guarantee maintenance and safety information Read this manual carefully before commencing installation This manual covers the following products CE compliant product Monsoon Extr...

Page 2: ...wledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user...

Page 3: ...supplied must be fitted to allow easy pump service 28 mm copper outlet pipework discharge Short 28 mm copper pipe tails to connect between isolating valve and flexible pipes 28 mm isolating valve non...

Page 4: ...esign of pipework runs to minimize the risk of air locks e g use drawn bends rather than 90o bends 1 18 DO NOT introduce solder flux to flexible hoses pumps or pump parts manufactured from plastic 1 1...

Page 5: ...ure The pump must be sited in a location where the maximum ambient temperature does not exceed 40 o C 2 19 Pipework For optimum performance pipework use 28 mm dia 22 mm can be used but will result in...

Page 6: ...cold water supply Must be a DEDICATED AIR FREE supply via a tank connector Do not connect to the mains Fig 2 Cold water Hot water Unvented hot water cylinder Static inlet pressure Min 1 m Max 10 m Sta...

Page 7: ...d The hose end is made water tight with a sealing washer on assembly nip tight to 4 5 Nm for water tight seal Do not overtighten 3 12 Hose to pipework Hoses terminating in G 1 threaded connections are...

Page 8: ...be safely routed and secured by cable clips 4 15 Supplementary Bonding The pressure set is factory fitted with a supplementary earthing wire to ensure continuity throughout the assembly Fig 3 It must...

Page 9: ...d of this appliance may not correspond with the coloured markings identifying the terminals in your connection unit proceed as follows The wire which is coloured green and yellow must be connected to...

Page 10: ...and routing system Re assemble to the same pattern For information on cable connection consult the wiring diagram and cable gland fitting instructions 4 25 Cable Gland Fitting Instructions To enable...

Page 11: ...ined to help and advise you over the phone 5 COMMISSIONING SYSTEM FLUSHING PRIMING STARTING 5 11 System Flushing The pipework system should be flushed out prior to the pump being connected to ensure a...

Page 12: ...n water supplies connect power supply and test 6 13 Pressure vessel The pressure vessel should be checked once every 6 months to have its air charge checked or replenished this should be carried out a...

Page 13: ...particularly applies to guest bathrooms used infrequently 6 15 Cleaners Disinfectants and Descalents Acid based descalents and aggressive cleaning agents must not come into contact with the pump The...

Page 14: ...sumption 775 Watts 1136 Watts Full load current 3 5 Amps 5 1 Amps Rating Continuous S1 Continuous S1 Max No Starts per hour 60 60 Mechanical Min inlet head 1 metres 1 metres Max inlet head 10 metres 1...

Page 15: ...n in accordance with manufacturers instructions No hot water Air locked water feed Vent hot water pump of air Check cold feed to hot water cylinder Check water level in cold water tank and that all st...

Page 16: ...nd if the water starvation condition remains present the pump will then stop operation after a 1 minute period 6 The pump will remain in the off condition for a period of 5 minutes 7 The pump will the...

Page 17: ...l box lid ensuring no cables are trapped Re fit the four terminal box lid retaining screws tighten to 0 8 Nm 8 14 Environment Protection Your appliance contains valuable materials which can be recover...

Page 18: ...ump rating label and the back page of the installation instructions 2 Your name address telephone e mail 3 The date of installation Within the guarantee period we will repair free of charge any defect...

Page 19: ...ty to quickly locate an installer in their area Registration is free simply click on the register as an installer link on our homepage at www stuart turner co uk and complete a short form which will e...

Page 20: ...OR DRIVEN PUMP AS SERIAL NUMBER BELOW COMPLIES WITH THE ESSENTIAL REQUIREMENTS OF THE ABOVE E E C DIRECTIVES RESPONSIBLE PERSON AND MANUFACTURER STUART TURNER LIMITED HENLEY ON THAMES OXFORDSHIRE RG9...

Reviews: