- 10 -
Cont ...
4.24
Supply Cord Replacement:
The supply cord and internal wiring within the terminal box are
routed and secured to ensure compliance with the electrical
standard EN 60335-1. It is essential that prior to any disturbance
of this internal wiring, all cable routing and securing details are
carefully noted to ensure re-assembly to the same factory pattern
is always maintained.
If the supply cord is to be changed or is damaged, it must be replaced with a
special cord assembly available from Stuart Turner or one of their approved
repairers.
On disassembly note the cord retention and routing system. Re-assemble to the
same
pattern.
For information on cable connection consult the wiring diagram and cable gland
fitting
instructions.
4.25
Cable Gland Fitting Instructions:
To enable correct assembly of the cable gland the ‘O’-ring (Fig. 6 item 1) must
be placed over the cable before the clamping insert (Fig. 6 item 2) can
be
tightened.
Note: Cable diameter range:- 6.5 mm to 9.5 mm.
4.26
Supply Cord Extension:
The pumps are fitted with a supply cord to the following specification:-
All models . . . . . . . . . . . . . . . . . HO5VV-F3 G 0.75 mm² - 6 Amp rated cable.
If the supply cord is to be extended, a cord of the same specification should be
used. Any connections or junction boxes used should be specifically suited for
the application and installed in accordance with the manufacturers instructions.
Fig. 6
2
1