www.stryker.com
3006-209-001 REV B
7
Introduction
This manual assists you with the operation or maintenance of your Stryker product. Read this manual before operating
or maintaining this product. Set methods and procedures to educate and train your staff on the safe operation or
maintenance of this product.
CAUTION
•
Improper usage of the product can cause injury to the patient or operator. Operate the product only as described in
this manual.
•
Do not modify the product or any components of the product. Modifying the product can cause unpredictable
operation resulting in injury to patient or operator. Modifying the product also voids its warranty.
Notes
•
This manual is a permanent part of the product and should remain with the product even if the product is sold.
•
Stryker continually seeks advancements in product design and quality. This manual contains the most current
product information available at the time of printing. There may be minor discrepancies between your product and
this manual. If you have any questions, contact Stryker Customer Service or Technical Support at 1-800-327-0770.
Product description
The
3002 S3®
® MedSurg Bed
has fowler, gatch and lift articulation capabilities that aide in the adjustment of surface
contour, angle, and height. The product offers various options outlined in the product operations manual, including but
not limited to
i
Bed®
®
Awareness, scale, 110V AC option, IV pole, and defibrillator tray.
i
Bed
Awareness allows operators
to set various bed parameters to monitor bed positioning. Alerts inform operators to patient movement within a specific
zone(s) on a patient surface. The product may be equipped with an integrated scale intended to weigh the patient in bed.
Both
i
Bed
Awareness and
Chaperone®
®
bed exit systems provide both visual and audible alerts.
Indications for use
The 3002
S3
MedSurg bed is intended to support and transport patients within the Med/Surg and Critical Care hospital
environments. The 3002
S3
MedSurg bed is typically used in pre-op, post-op and recovery areas of hospital facilities.
The intended user for this product is both health care providers (HCP), such as, nurses, nurses’ aides, medical doctors,
and human patients. Lockout features may limit patient accessible controls. Use this product with a patient sleep
surface. The scale output is not intended to be used to determine diagnosis or treatment.
The intended patient population for the 3002
S3
MedSurg bed includes:
•
Patients above 50 lb with a safe working load of 500 lb
•
Patients at least 2 years of age
•
Patients less than 84 in. without a bed extender or 96 in. with a bed extender
The product is not intended to support more than one individual at a time.
Indications for use for
i
Bed Wireless
The intended use for
i
Bed
Wireless (with
i
Bed
Awareness system) is to assist clinical staff to monitor bed parameters
on specific Stryker beds. The desired bed parameters are set by operators at the bedside.
i
Bed
Wireless is only
intended for use with specifically enabled Stryker beds that have been verified and validated with
i
Bed
Wireless, and is
not intended to provide bed status information for non-Stryker beds.
i
Bed
Wireless is not intended to communicate any
patient status information, nor to permanently store any type of data.
i
Bed
Wireless with
i
Bed
Awareness system is not
intended to provide automated treatment decisions or as a substitute for professional healthcare judgment.
i
Bed
Wireless with
i
Bed
Awareness system is not a replacement or substitute for vital signs monitoring or alert equipment. All
patient medical diagnosis and treatment are to be performed under direct supervision and oversight of an appropriate
healthcare professional.