Case Lights Are Not 
Working 

Follow previous page’s 

System Not Operating

 instructions.

 

 

Check voltage at LED driver.  If voltage is entering but not exiting, LED driver 
may be faulty.

 

 

Check connection at front of case (from circuit breaker) for voltage. 

 

Check connection at case rear (from field wiring box) for voltage. 

One (or Several) Case 
Lights are Not Working 

Follow previous page’s 

System Not Operating

 instructions.

 

 

If case light still do not come on, call 

SCC Technical Service 

phone number 

(listed on last page of this operating manual).

 

Control Display Is 
Flashing 

See your case’s serial label for your model’s specified settings.  See SERIAL 
LABEL LOCATION & INFORMATION LISTED / TECH INFO & SERVICE
      

for label location, etc.

 

Case Is Not Holding       
Temperature 

If a large amount of warm product was added to the case, it will take time for 
the temperature to adjust.  Unit needs product to be pre-chilled. 

 

Temperature changes during defrost mode but will return to normal.  Fourth 
LED (on temperature controller) will indicate defrost cycle in progress. 

 

Check that case is not in sun or near a heat or air-conditioning vent. 

 

If case is located near front doors, temperature fluctuation can hinder unit’s 
ability to maintain temperature. 

 

Check air grilles for obstructions. 

 

If no case light STILL do not come on, call 

SCC Technical Service 

phone 

number (listed on last page of this operating manual).

 

Summary of Contents for FSE663R

Page 1: ...38 pub REFRIGERATED SELF SERVICE ISLAND CID MODELS FSI856R FSI656R FSI663R and FSI863R REFRIGERATED SELF SERVICE PENINSULA END CAP CID MODEL FSE663R 888 E Porter Road Muskegon MI 49441 Phone 231 798 8...

Page 2: ...DRAIN LAYOUT REFRIGERATION FUNDAMENTALS SELF CONTAINED DRAIN LAYOUT REFRIGERATION FUNDAMENTALS CONDENSATE PACKAGE ACCESS REFRIGERATION FUNDAMENTALS CONDENSATE PACKAGE ILLUSTRATED PARTS BREAKDOWN GENE...

Page 3: ...sheet contains important warnings to prevent injury or death Please read carefully PRECAUTIONS MAINTENANCE WIRING DIAGRAM INFORMATION See next page for PRECAUTIONS MAINTENANCE and WIRING DIAGRAM info...

Page 4: ...the following before powering up case Condensate pump must be plugged into receptacle Condensate lines must be connected to condensate pump CAUTION CHECK BOTH CONDENSATE PAN AND OVERFLOW PAN Water on...

Page 5: ...CE REMOVAL 5 Enlarged View of Shipping Brace For In Line Casters Shown Removed Shipping Brace Attachment Holes Typ Either discard or recycle See illustration below 3 Shipping Brace For In Line Casters...

Page 6: ...ift truck Move into position KICK PANEL REMOVAL REMOVAL OF CASE FROM PALLET POSITIONING UNIT 6 3 J Bar or Dolly Only No Fork Lift Slide case to edge of pallet With several people in position carefully...

Page 7: ...may be shimmed to assure that it is level Shims will be provided with such cases Illustration below shows case with frame support rails Note After case has been properly shimmed attach panels No screw...

Page 8: ...wer levelers until the case is raised off its casters Level case by turning levelers as necessary 3 Raise Levelers Levelers may be raised to allow case to be slid to new location Simply raise levelers...

Page 9: ...gh Protective Plate Shown After Removal of Knock Outs Caution If ceiling originated lines are used you MUST seal both upper and lower PVC pass throughs at entrance points with expandable foam sealant...

Page 10: ...ormed by licensed refrigeration contractor 2 Refrigeration Lines at Underside Underside refrigeration lines are standard Refrigeration lines are ALWAYS at rear of case See photograph immediately below...

Page 11: ...r before providing maintenance and service to unit Assembly disassembly servicing to be performed by licensed refrigeration contractor Condensate pump is located just behind ballast box as shown in il...

Page 12: ...l Removal To remove panel and access field wiring box lift panel up and off case hooks by grasping firmly and pulling up and outward and separating from retaining magnets 3 Self Contained Cases Only M...

Page 13: ...l be maintained by following these instructions A Horizontally vented toe kick must be attached to intake side of compressor as shown in item A B Vertically vented toe kick must be attached to the dis...

Page 14: ...Product 1 Min Product 1 Min Product 1 Min Product Top Shelf RESTRICTED FOOD PRODUCTS SALADS GARDEN CHEF CHICKEN BLT ETC PLACE ON SIDE DECKS ONLY CHEESE STICKS PLACE ON SIDE DECKS OR END CAP DECKS Mid...

Page 15: ...on rear plenum at upper area of case Digital thermometer is on ALL merchandisers The Check Temperature thermometer is optional See illustrations below Digital Thermometer Optional Check Temperature Th...

Page 16: ...s check to see that the coil fans are all functioning properly Solenoid location shown on illustration may be on remote cases ONLY View of Evaporator Coil Fans TXV and Drains After Decks and Upper Can...

Page 17: ...17 MAINTENANCE FUNDAMENTALS SHELF BRACKET ASSEMBLY REMOVAL 1 Shelf Bracket Assembly Removal Shelving is fixed it is not adjustable Screws must be removed to remove shelves See illustrations below...

Page 18: ...ction of the case LED light fixtures MAY ALSO be located on shelving as shown in photos below 4 LED Light Fixture Removal and Replacement This case is provided with mini LED lights which will rarely r...

Page 19: ...ly Illustration below shows location of refrigeration lines for remote connection Two 2 drains accessible from top of unit by lifting up decking See POWER UP CHECK EVAPORATOR FAN AREA section in this...

Page 20: ...Only Illustration below shows location of refrigeration lines for self contained operation Four 4 drains accessible from top of unit by lifting up decking See POWER UP CHECK EVAPORATOR FAN AREA sectio...

Page 21: ...o case Turn case back on See next page for complete illustrated parts breakdown of condensate package after removal from underside of case Self Contained Units Access to Condensate Package Assembly di...

Page 22: ...frigeration U Tubes Filter Dryer Electrical Starter Unit Condenser Coil Housing Condenser Coil Fan Fan Housing Motor Overflow Condensate Pan Hot Gas Loop Condensate Pan Wicking Material Optional Sight...

Page 23: ...spray bottle to spray components Wipe with paper towel Use RINSE spray bottle on components Dry with paper towel Use SANITIZE spray bottle on shelving brackets and molding Let air dry Return product t...

Page 24: ...c condenser coil air filter from inside of lower panel 3 Use a soft bristled brush or paper towel to wipe Magnetized Condenser Coil Air Filter off excess dust particles and debris from filter DO NOT u...

Page 25: ...are sharp Handle with care Replace lower panel in reverse order it was removed See sample condenser coil cleaning brushes at right Quarterly Refrigeration Package Compressor Components Self Contained...

Page 26: ...retainer C Pry downward and away from honeycomb retainer If honeycomb is dirty allow to soak in hot soapy water in back room pot sink Use nylon brush to remove dust A B C D E F debris and stubborn or...

Page 27: ...connect at the red dot marker at the end of the LED lamp See MAINTENANCE FUNDAMENTALS SHELF BRACKET ASSEMBLY REMOVAL LIGHT FIXTURES section in this manual for more specifics including illustrations If...

Page 28: ...ounted in brackets Verify that fan blades are securely mounted to fan motor Check that nothing is preventing blade rotation Check that the fan shroud is properly secured Fans Are Not Working Check tha...

Page 29: ...Control Display Is Flashing See your case s serial label for your model s specified settings See SERIAL LABEL LOCATION INFORMATION LISTED TECH INFO SERVICE for label location etc Case Is Not Holding T...

Page 30: ...system Check that liquid line filter dryer is not plugged Check that close offs are intact around condensing coil and that air is not recirculating Check that store ambient temperature isn t above max...

Page 31: ...e is no air recirculation around evaporator coil Check that evaporator coil is not iced up High Suction Pressure Check for refrigerant overcharge Check that compressor reed valves aren t bad Look for...

Page 32: ...well as regulatory standards to which the case conforms For additional technical information and service see the TECHNICAL SERVICE page in this manual for instructions on contacting Structural Concep...

Page 33: ...timeout occur normal operational settings prior to modifications being made will resume 3 If the instrument is switched off before pressing the Prg key all modifications to parameters will be lost Se...

Page 34: ...set reset HACCP alarms reset temp monitoring Summary Table of Alarm and Signals Display Buzzer and Relay Integrated Electronic Microprocessor Controller Read And Save These Instructions Page 2 of 3 Us...

Page 35: ...tor min F 1 250 d6 Display on hold during defrost C 0 2 dd Dripping time after defrost min F 0 15 d 1 Display of defrost probe 1 C F F 5 Select Celsius C or Fahrenheit F flag C 0 1 35 For Case Specifi...

Page 36: ...ent by Purchaser Liabilities shall include all costs claims damages judgments and expenses including reasonable attorney fees and costs Remedies of SCC SCC s rights and remedies shall be cumulative an...