CODE 

PARAMETER 

UOM* 

TYPE  MINIMUM  MAXIMUM 

DEFAULT 

/c1 

Calibration of probe 1 

°C/°F 

-20 

20 

 

/c2 

Calibration of probe 2 

°C/°F 

-20 

20 

St 

Temperature set point 

°C/°F 

r2 

r1 

rd 

Control delta 

°C/°F 

20 

0.1 

dl 

Interval between defrosts 

hours 

250 

dt1 

End defrost temperature, evaporator 

°C/°F 

-50 

200 

dP1 

Maximum defrost duration, evaporator 

min 

250 

d6 

Display on hold during defrost 

dd 

Dripping time after defrost 

min 

15 

d/1 

Display of defrost probe 1 

°C/°F 

/5 

Select Celsius (°C) or Fahrenheit (°F) 

flag 

35 

For Case  

Specific  

Defaults  

See Serial 

Label 

Located  

Near 

Electrical 

Access 

On Your 

Case. 

 

For 

Additional 

Technical 

Information 

Call 

Structural 

Concepts 

Technical 

Service 

Dept. at 

1(800) 

433.9489 

* Unit Of Measure 

Read And Save These Instructions - Page 3 of 3 

Integrated Electronic 

 Microprocessor Controller 

Summary Table of Operating Parameters 

Summary of Contents for FSE663R

Page 1: ...38 pub REFRIGERATED SELF SERVICE ISLAND CID MODELS FSI856R FSI656R FSI663R and FSI863R REFRIGERATED SELF SERVICE PENINSULA END CAP CID MODEL FSE663R 888 E Porter Road Muskegon MI 49441 Phone 231 798 8...

Page 2: ...DRAIN LAYOUT REFRIGERATION FUNDAMENTALS SELF CONTAINED DRAIN LAYOUT REFRIGERATION FUNDAMENTALS CONDENSATE PACKAGE ACCESS REFRIGERATION FUNDAMENTALS CONDENSATE PACKAGE ILLUSTRATED PARTS BREAKDOWN GENE...

Page 3: ...sheet contains important warnings to prevent injury or death Please read carefully PRECAUTIONS MAINTENANCE WIRING DIAGRAM INFORMATION See next page for PRECAUTIONS MAINTENANCE and WIRING DIAGRAM info...

Page 4: ...the following before powering up case Condensate pump must be plugged into receptacle Condensate lines must be connected to condensate pump CAUTION CHECK BOTH CONDENSATE PAN AND OVERFLOW PAN Water on...

Page 5: ...CE REMOVAL 5 Enlarged View of Shipping Brace For In Line Casters Shown Removed Shipping Brace Attachment Holes Typ Either discard or recycle See illustration below 3 Shipping Brace For In Line Casters...

Page 6: ...ift truck Move into position KICK PANEL REMOVAL REMOVAL OF CASE FROM PALLET POSITIONING UNIT 6 3 J Bar or Dolly Only No Fork Lift Slide case to edge of pallet With several people in position carefully...

Page 7: ...may be shimmed to assure that it is level Shims will be provided with such cases Illustration below shows case with frame support rails Note After case has been properly shimmed attach panels No screw...

Page 8: ...wer levelers until the case is raised off its casters Level case by turning levelers as necessary 3 Raise Levelers Levelers may be raised to allow case to be slid to new location Simply raise levelers...

Page 9: ...gh Protective Plate Shown After Removal of Knock Outs Caution If ceiling originated lines are used you MUST seal both upper and lower PVC pass throughs at entrance points with expandable foam sealant...

Page 10: ...ormed by licensed refrigeration contractor 2 Refrigeration Lines at Underside Underside refrigeration lines are standard Refrigeration lines are ALWAYS at rear of case See photograph immediately below...

Page 11: ...r before providing maintenance and service to unit Assembly disassembly servicing to be performed by licensed refrigeration contractor Condensate pump is located just behind ballast box as shown in il...

Page 12: ...l Removal To remove panel and access field wiring box lift panel up and off case hooks by grasping firmly and pulling up and outward and separating from retaining magnets 3 Self Contained Cases Only M...

Page 13: ...l be maintained by following these instructions A Horizontally vented toe kick must be attached to intake side of compressor as shown in item A B Vertically vented toe kick must be attached to the dis...

Page 14: ...Product 1 Min Product 1 Min Product 1 Min Product Top Shelf RESTRICTED FOOD PRODUCTS SALADS GARDEN CHEF CHICKEN BLT ETC PLACE ON SIDE DECKS ONLY CHEESE STICKS PLACE ON SIDE DECKS OR END CAP DECKS Mid...

Page 15: ...on rear plenum at upper area of case Digital thermometer is on ALL merchandisers The Check Temperature thermometer is optional See illustrations below Digital Thermometer Optional Check Temperature Th...

Page 16: ...s check to see that the coil fans are all functioning properly Solenoid location shown on illustration may be on remote cases ONLY View of Evaporator Coil Fans TXV and Drains After Decks and Upper Can...

Page 17: ...17 MAINTENANCE FUNDAMENTALS SHELF BRACKET ASSEMBLY REMOVAL 1 Shelf Bracket Assembly Removal Shelving is fixed it is not adjustable Screws must be removed to remove shelves See illustrations below...

Page 18: ...ction of the case LED light fixtures MAY ALSO be located on shelving as shown in photos below 4 LED Light Fixture Removal and Replacement This case is provided with mini LED lights which will rarely r...

Page 19: ...ly Illustration below shows location of refrigeration lines for remote connection Two 2 drains accessible from top of unit by lifting up decking See POWER UP CHECK EVAPORATOR FAN AREA section in this...

Page 20: ...Only Illustration below shows location of refrigeration lines for self contained operation Four 4 drains accessible from top of unit by lifting up decking See POWER UP CHECK EVAPORATOR FAN AREA sectio...

Page 21: ...o case Turn case back on See next page for complete illustrated parts breakdown of condensate package after removal from underside of case Self Contained Units Access to Condensate Package Assembly di...

Page 22: ...frigeration U Tubes Filter Dryer Electrical Starter Unit Condenser Coil Housing Condenser Coil Fan Fan Housing Motor Overflow Condensate Pan Hot Gas Loop Condensate Pan Wicking Material Optional Sight...

Page 23: ...spray bottle to spray components Wipe with paper towel Use RINSE spray bottle on components Dry with paper towel Use SANITIZE spray bottle on shelving brackets and molding Let air dry Return product t...

Page 24: ...c condenser coil air filter from inside of lower panel 3 Use a soft bristled brush or paper towel to wipe Magnetized Condenser Coil Air Filter off excess dust particles and debris from filter DO NOT u...

Page 25: ...are sharp Handle with care Replace lower panel in reverse order it was removed See sample condenser coil cleaning brushes at right Quarterly Refrigeration Package Compressor Components Self Contained...

Page 26: ...retainer C Pry downward and away from honeycomb retainer If honeycomb is dirty allow to soak in hot soapy water in back room pot sink Use nylon brush to remove dust A B C D E F debris and stubborn or...

Page 27: ...connect at the red dot marker at the end of the LED lamp See MAINTENANCE FUNDAMENTALS SHELF BRACKET ASSEMBLY REMOVAL LIGHT FIXTURES section in this manual for more specifics including illustrations If...

Page 28: ...ounted in brackets Verify that fan blades are securely mounted to fan motor Check that nothing is preventing blade rotation Check that the fan shroud is properly secured Fans Are Not Working Check tha...

Page 29: ...Control Display Is Flashing See your case s serial label for your model s specified settings See SERIAL LABEL LOCATION INFORMATION LISTED TECH INFO SERVICE for label location etc Case Is Not Holding T...

Page 30: ...system Check that liquid line filter dryer is not plugged Check that close offs are intact around condensing coil and that air is not recirculating Check that store ambient temperature isn t above max...

Page 31: ...e is no air recirculation around evaporator coil Check that evaporator coil is not iced up High Suction Pressure Check for refrigerant overcharge Check that compressor reed valves aren t bad Look for...

Page 32: ...well as regulatory standards to which the case conforms For additional technical information and service see the TECHNICAL SERVICE page in this manual for instructions on contacting Structural Concep...

Page 33: ...timeout occur normal operational settings prior to modifications being made will resume 3 If the instrument is switched off before pressing the Prg key all modifications to parameters will be lost Se...

Page 34: ...set reset HACCP alarms reset temp monitoring Summary Table of Alarm and Signals Display Buzzer and Relay Integrated Electronic Microprocessor Controller Read And Save These Instructions Page 2 of 3 Us...

Page 35: ...tor min F 1 250 d6 Display on hold during defrost C 0 2 dd Dripping time after defrost min F 0 15 d 1 Display of defrost probe 1 C F F 5 Select Celsius C or Fahrenheit F flag C 0 1 35 For Case Specifi...

Page 36: ...ent by Purchaser Liabilities shall include all costs claims damages judgments and expenses including reasonable attorney fees and costs Remedies of SCC SCC s rights and remedies shall be cumulative an...

Reviews: