background image

PARTS  LIST

Figure 1

Item Part No.

Description

  1

62-40121

Top Cover Panel

  2

62-40095

Side Panel (Left)

  3

62-40123

Vented Panel, Rear

  4

62-40101

Rear Panel Bracket

  5

62-80105

Power Module (See Figure 2)

  6

62-40096

Base Plate

  7

62-40098

Brace Panel

  8

62-40102

Vented Panel, Front

  9

62-40118

Side Panel (Right)

 10

77271000

Handle, Spring-Loaded

 11

62-40097

Front Panel Bracket

 12

41-51540

Panel Mounting Screw, 8-32 x 3/8"

 13

62-80036

Name & Data Plate

9

Summary of Contents for xenon

Page 1: ...XENON POWER SUPPLY Compact Model Type 62 80100 Issue 12 98 STRONG INTERNATIONAL a division of Ballantyne of Omaha Inc 4350 McKinley Street Omaha Nebraska 68112 USA Tel 402 453 4444 Fax 402 453 7238 ...

Page 2: ......

Page 3: ...ER reduces the incoming line to 120 V AC to power the lamphouse igniter and blower s A separate three ampere circuit breaker protects the control circuit in the event of a lamphouse component malfunction PROTECTIVE CIRCUITS include a high temperature limit switch and under and overvoltage detection The thermal switch will open and interrupt power supply operation if internal temperatures exceed 17...

Page 4: ...to terminals X and Z only Single or three phase neutral is not required for installation of this unit Attach an adequate earth ground to the green ground terminal In areas using 380 440 V AC three phase power Europe etc connect the unit for single phase operation only using 1 phase line on X and a neutral on Z AC input as measured across connector terminals X and Z must not exceed 240 V AC Attach ...

Page 5: ...he AC lamphouse igniter A second two terminal barrier strip located next to the DC output terminals is in cluded in spotlight power supplies Wires 7 8 220 V AC terminate at this position and supply voltage to lamphouse blowers in Gladiator III spotlights through MS connector Pins I J These wires are unused in Super Trouper and other spotlights but are included to permit interchanging power supplie...

Page 6: ...w Thermal switches mounted to the power supply will interrupt operation of the power supply in the event of overheating The blower motors are permanently lubricated The 62 80100 power supply includes 2 blowers and requires operation of both fully functional blowers for correct operation In the event of a blower failure a replacement blower must be installed immediately Service interruptions becaus...

Page 7: ...ard is receiving the correct DC input VIN Indicates that the AC input voltage is within the correct range 200 240 V AC FUSE Indicates that the fuses on the primary boards are good GO Indicates that the lamphouse interlock circuit is complete and that DC power is being applied to the xenon bulb RED LIGHTS TEMP Indicates that the unit is overheated VIN Indicates that AC input voltage is above or bel...

Page 8: ...ladiator III Ultra 80 lamphouse wires 7 8 should measure 220 V AC 9 Lamphouse blower fuse blown if applicable See schematic in lamphouse manual 10 Defective lamphouse blower Check AC voltage at blower motor inputs should measure 100 120 V AC Gladiator III Ultra 80 lamphouse blower 220 V AC Replace if defective Lamphouse Blower s Operate but Power Supply GO Indicator does not glow 1 No voltage on t...

Page 9: ... ignition if no ping is audible in the lamphouse replace igniter If ping is audible but no flash is apparent check for lamphouse DC lead shorting to ground If ping is heard and arc is visible between bulb electrodes and bulb fails to ignite replace bulb Xenon Bulb Goes Out During Operation Intermittent Operation 1 Defective or expired xenon bulb Replace as required 2 Fault in lamphouse interlock c...

Page 10: ...FIGURE 1 5 See Figure 3 1 2 3 4 6 7 8 9 10 11 12 13 8 ...

Page 11: ...Panel Rear 4 62 40101 Rear Panel Bracket 5 62 80105 Power Module See Figure 2 6 62 40096 Base Plate 7 62 40098 Brace Panel 8 62 40102 Vented Panel Front 9 62 40118 Side Panel Right 10 77271000 Handle Spring Loaded 11 62 40097 Front Panel Bracket 12 41 51540 Panel Mounting Screw 8 32 x 3 8 13 62 80036 Name Data Plate 9 ...

Page 12: ...FIGURE 2 1 2 3 4 5 6 7 8 9 10 11 12 13 5 14 15 16 17 18 17 19 10 ...

Page 13: ... 62 70015 Primary Module Assembly 81 21001 Fuse 15 Ampere 2 req d 8 62 20027 Primary Buss Bar 9 62 70020 Secondary Module Assembly 10 62 20028 Output Buss Bar 11 41 35060 Locknut 1 4 20 61 70002 Spring Washer 12 41 51032 Screw 6 32 x 1 4 Bind Head 13 62 40093 Lower Shield 14 41 51413 Screw 6 32 x 5 8 Phillips Head 15 62 40094 Fan Panel 16 61127000 Fan Clip 6 32 17 61 98002 Fan 115 V AC 50 60 Hz 18...

Page 14: ...FIGURE 3 1 2 3 5 6 7 8 7 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 4 12 CURRENT CONTROL to Item 18 62 70028 Plug In PC Board Assembly no Cable 62 70032 Potentiometer Cable Assembly Remote ...

Page 15: ...former AC Control 14 61 98035 Line Filter 15 41 98045 Grommet 16 62 70026 LEM Harness 17 62 40128 MS Receptacle Mounting Panel 18 61 13007 Amphenol Plug 15 Pin 19 62 70025 MS Connector Wired Assembly 88319000 MS Receptacle 14 Pin Female 20 62 40116 Mounting Plate 21 61 40007 AC Input Receptacle 30 Ampere Hubbell 22 41 51540 Screw 8 32 x 3 8 Phillips Head 23 41 51413 Screw 6 32 x 5 8 Phillips Head ...

Page 16: ...s 14 DB 15 Connector Pin 1 Com Signal 2 I Signal 20mv a 3 GO Signal Input 4 Power Section Fault 5 Inhibit Fault 6 not used 7 9 V 8 9 V Return 9 V Signal 20 mv v 10 9 V Return 11 9 V 12 Enable Fault 13 not used 14 I Adjust Fine 15 I Adjust Coarse ...

Page 17: ......

Page 18: ......

Reviews: