38
MA_441-1-2_A1_180830_en
-
Add a new sector with the "E" button or knee switch.
-
Set the differential transport and save with "P" button.
-
During saving, the second associated program is adapted
automatically (e.g. 00R+01L, 02R+03L, 04R+05L…)
-
Return to the display "Standard".
Delete last sector
-
Activate programming mode.
-
Select and confirm program number.
-
Press the "F1" button to display last sector.
-
Press the "F2" button to delete the last sector ("Delete" is displayed).
-
Press the "E" button to confirm the entry.
-
The "P" button cancels the deletion process.
-
If cancelling, return to display "Programming mode".
Summary of Contents for 441-1
Page 4: ......
Page 13: ...9 MA_441 1 2_A1_180830_en The lifting value between the feed cups is 12 14 mm...
Page 17: ...13 MA_441 1 2_A1_180830_en Fig 5...
Page 25: ...21 MA_441 1 2_A1_180830_en Fig 11...
Page 45: ...41 MA_441 1 2_A1_180830_en Parameter 714 1...
Page 48: ...44 MA_441 1 2_A1_180830_en 4 17 7 Brief instruction Class 441 2...
Page 64: ......