24
MA_441-1-2_A1_180830_en
4.11
After loosening the clamping screw (1) (
Replacing the looper
Fig. 14) at the head of the looper shaft
(2), the looper can be removed.
When inserting a new looper, make sure that it contacts the needle or feed cup
neither when it is in the front nor when it is in the rear position(see also
installation dimension (L), point "2.5 Abridged version of adjustment manual").
The wide looper back should be set up as parallel as possible to the needle.
Fig. 14
Summary of Contents for 441-1
Page 4: ......
Page 13: ...9 MA_441 1 2_A1_180830_en The lifting value between the feed cups is 12 14 mm...
Page 17: ...13 MA_441 1 2_A1_180830_en Fig 5...
Page 25: ...21 MA_441 1 2_A1_180830_en Fig 11...
Page 45: ...41 MA_441 1 2_A1_180830_en Parameter 714 1...
Page 48: ...44 MA_441 1 2_A1_180830_en 4 17 7 Brief instruction Class 441 2...
Page 64: ......