Control Panel
Three levels and four positions rotary switch, which can be turned from 0 to 360 degree clockwise or counter
clockwise, the first level is ventilator only, the second level is 4.5KW and the third level is full power input.
You can adjust the level clockwise or reverse.
0
~
40
C adjustable thermostat to control the room temperature
,
the thermostat button can be turned from
0 to 270 degree.
THERMOSTAT INSTRUCTIONS
At first turn the thermostat to “Max” and let the heater operate with full power input. When the room
temperature reaches the required value, turn the thermostat to left until it switches off.
The thermostat will then switch on and off automatic to control the room temperature according to the
preset value and keep the room temperature constant.
Manual reset thermal cut-out
By overheating or abnormal operation and meanwhile the thermostat fails to work, the manual resetting
thermal cut-out will act and shut down the appliance. Remove the plug from the socket and let the appliance
cool down, then use the provided steel pin to touch the manual resetting button. When you hear a clear click
it means the electric circuit is put through, put the plug back into the socket and switch the heater on. (see
the figure manual “RESET” button)
When using the heater for the first time, you may notice a slight emission of smoke. This is quite normal and
it stops after a short time. The heating element is made of steel and was coated with a layer of protection oil
by production. The smoke is caused by the left oil when heated.