PZ0064
www.securitycamera2000.com
25
NORMAL REC RATE:
normal record rate, two option:
NORMAL:
MDVR will start to record according to the setup of RECORD SETTING.
I FRAME:
MDVR only record at I frame in order to take less space of hard drive. BUT when event is trigged,
MDVR will record according to setup of RECORD SETTING.
ALARM PRE-REC TIME
(
1-60
)
MIN:
pre-record time setting from 1 to 60 minutes. For example: If the setting for
pre-record is 30min, when alarm trigger at 10:30, then the record file start
from 10:00 to 10:30 will pack as alarm record.
(Make sure the Pre-recording switch is ON when you want to use this function)
ALARM DURATION
(
3-30
)
SEC:
the alarm duration time, All the alarm for same type considered to be one alarm
during the setting for alarm duration and MDVR reset the duration time
automatically. For example, if the setting for alarm duration is 10 sec and
during this 10 sec, anther same type alarm triggered and then MDVR system
will consider them to be one alarm event. And the alarm start time will be reset
based on the second time for alarm.
ALARM POST REC
(
30-1800
)
SEC:
alarm post recording time setting.
BUZZER ALARM TIME:
buzzer alarm duration time setup, when alarm triggered, the buzzer duration time.
MEDADATA CAPTURE:
metadata information.
RECORD FILE TIME
(
MIN
)
:
recording file packing size, 15, 30,45,60 minutes optional
HDD/SD OVERWRITE:
To make the HDD overwrite when there is only 2GB space in HDD.
ON:
when hard drive space less than 2G, according to “First in first out” rule, system will start to delete the
earliest record files till HDD space equal or over 10G (except the alarm file which in locked time).
OFF:
Device will stop recording when hard drive space is full (less than 500M), you must replace an HDD or
delete recording file manually, then it will start to record.
LOCKED FILE RETENTION (DAY):
Locked recording file save time: 7, 10, 15, 20, 30, 45 days optional, during
the save time, the locked recording file won’t be deleted. Once pass lock time, the recording file LOCK
identifier will be from L to U, and then can be deleted.
PRE-RECORDED SWITCH
: ON/OFF, ON means enable the function of pre-recording, OFF means not.