3.
Click
DMS
for calibration
4.
Choose the channel corresponding to the DMS camera
5.
Click
Calibration
for the next step
6.
Confirm the prompt--Click
Next
for the next step
7.
For the installation location of the DMS camera, the left A-pillar, the right
A-pillar, the front side of the countertop, and the lateral side of the countertop
are available. If you have any questions, please click each option in turn, and
refer to the legend and description on the right.
After selecting the corresponding installation method, the software automatically
associates the calibration method with the installation method, not requiring any
manual operation (for installation on the left A-pillar, the right A-pillar, and the
lateral side of the countertop, the lateral side calibration is applied, and for the
installation on the front side of the countertop, the front side calibration is applied).
(This step is very important, and the selected installation method must be consistent