Removal of burner & convection box

1.  Turn off the gas supply by the isolation cock.
2.  Disconnect the 8mm pipe from the elbow at the left hand side of the burner.
3.  Slacken the grub screw and pull off the control knob on the upper right hand side of

the case if fitted.  Slacken the two screws underneath the canopy, and slide the
canopy off. Remove the 2 screws securing the front casing (one each side, near the
bottom) and carefully remove the casing by sliding the left hand edge forward, then to
the right to clear the high level tap spindle. Place carefully to one side.

4.  Remove the 2 screws securing the burner to the convector box and remove the

burner. For a High Level Control version it will also be necessary to disconnect the
pipes at the gas tap and injector by undoing the union nuts.

5.  Remove the 4 screws in the flange of the convection box, and lift the box out of the

opening.

6.  Examine the flue for debris and clean if necessary.
7.  Reassemble in the reverse order.
8.  After servicing check for gas soundness.

Following a service, a check should be made for clearance of combustion products. Follow the
procedure detailed in these instructions.

Cleaning the fire

Black paint: 

Use only a clean damp cloth. Do not use any cleaning agents.

Brass parts: 

Fret

 - Use Brasso or Duraglit ensuring that it does not come into contact with the

black paint finish.

Brass frame

 - This has a laquered finish and should only be wiped with a damp cloth. Do not

use metal polish.

IMPORTANT - 

The paint finish is durable and heat resistant, however it will be damaged if

plaster, cement or wallpaper paste is allowed to come into contact with it. 

Protect the

appliance during re-building or decorating work.

Replacement of parts

Before commencing any servicing always ensure that the fire is isolated from the gas supply
and that the fire is cold. After servicing always check for gas soundness.

Replacement of gas tap/FSD/piezo igniter

1.  Turn off the gas supply by isolation cock.
2.  Lift off the front fret and remove the coals and ceramic blocks.
3.  Proceed with paragraphs 2-4 above, 'Removal of burner and convection box'
4.  Pull off control knob.
5.  Remove the 2 screws securing the Data Badge plate and remove the plate.
6.  Disconnect ignition lead to the igniter unit.
7.  Disconnect all gas connections to gas valve as well as the connection to the

thermocouple.

8.  Remove 2 screws securing the valve to the mounting bracket, and discard old

tap/FSD/piezo igniter complete.

9.  Assemble the new tap/FSD/piezo igniter on the mounting bracket. 

Ensure that the

filter is in position in the pilot outlet orifice on the tap body.

10.  Reassemble the appliance in reverse order.
11.  Replace the ceramic blocks and coals (see Fig. 4).
12.  Turn on the gas supply and check for soundness.

Note: The igniter is not replaceable separately.

Replacement of high level gas tap

(High level control version)

1.  Turn off the gas supply by isolation cock.
2.  Pull off the control knob on the upper right hand side of the case if fitted.  Slacken the

two screws underneath the canopy, and slide the canopy off. Remove the 2 screws
securing the front casing (one each side, near the bottom) and carefully remove the

Summary of Contents for FLAIRE

Page 1: ...he Environment and Building Standards Scotland Consolidated Regulations issued by the Scottish Development Board Current Gas Safety Installation and Use Regulations Failure to install this appliance correctly could lead to prosecution and render the guarantee invalid Attention is drawn to the latest edition of the following standards BS1251 Specifications of open fireplace components BS5440 Part 1...

Page 2: ...lume for debris collection conforming to Fig 2 A pre cast block flue conforming to the requirements of BS1289 with a minimum cross sectional area of 12 000 sq mm and a minimum dimension of 60mm See Fig 2 for minimum depth requirements Ensure that mortar fangs between the blocks do not protrude into the flueway It is essential that the flue terminal does not restrict the flue flow and complies with...

Page 3: ...A 15mm gas supply pipe should be brought to within 1M of the fireplace opening The connection to the burner can be made from the right or left hand side by a concealed pipe from behind the burner to the restricter elbow on the left hand side of the burner Pierce the membrane grommet fitted in the back of the convection box and pass the gas supply pipe through ready for connection to the burner 8mm...

Page 4: ...Flaire Issue 1 3 29 06 01 Page 4 of 11 ...

Page 5: ...bolts and backnuts 3 2 Adjustable nipples with clamp screws 4 4 Screweyes and wall plugs 1 Mark out and drill 4 holes in the back of the opening to suit wall plugs supplied See the drawing for dimensions Insert the screweyes and align to allow the wires to pass through vertically 2 If the convector box has not been pre punched for the wire ropes drill the top and back shown in the drawing removing...

Page 6: ... ceramic components are fragile and should be handled with care Refer to Figs 4 and 5 for positioning of ceramic fibre blocks and coals 5 Place the back ceramic on the burner against the back of the convector firebox 6 Place a flat ceramic pad against each side of the firebox with the angled corner facing forward The pads are identified L and R Position them each side of the back ceramic 7 Slide t...

Page 7: ...k should be seen at the tip of the ignition probe At the same time the pilot flame should light KEEP THE KNOB PRESSED IN FOR 10 SECONDS If the pilot should fail to light turn the control knob clockwise to the off position wait 3 minutes and repeat the procedure 3 When the pilot flame is alight the control knob should be allowed to spring out slightly Turn the knob fully anti clockwise to the high ...

Page 8: ...er is aware that the ceramic blocks and coals must be located in accordance with the instructions and that the appliance should be serviced at regular intervals by a competent person to ensure continued safe operation 3 Explain that this appliance is fitted with an oxygen depletion sensor incorporated into the pilot body Should the fire repeatedly extinguish itself the cause should be sought and r...

Page 9: ...l polish IMPORTANT The paint finish is durable and heat resistant however it will be damaged if plaster cement or wallpaper paste is allowed to come into contact with it Protect the appliance during re building or decorating work Replacement of parts Before commencing any servicing always ensure that the fire is isolated from the gas supply and that the fire is cold After servicing always check fo...

Page 10: ...Check that the injector is parallel to the slots which retain the front coals 5 Reassemble in reverse order 6 Turn on the gas supply and check for soundness Replacement of ignition pilot assembly 1 Repeat operations 1 5 as described for Replacement of gas tap FSD piezo igniter 2 Disconnect thermocouple connection to the gas tap FSD piezo igniter 3 Disconnect pipe from base of pilot burner tube 4 P...

Page 11: ...cepted unless this product has been installed and operated strictly in accordance with these manufacturer s instructions U K Registered Design 2040268 British Patent Application 9414887 1 Design right reserved Legge Fabheat Ltd Fig 8 Quest outline drawing without trim ...

Reviews: