Leak test & pressure test

1.  Turn on the main gas supply and check for gas soundness.
2.  Remove pressure test screw, and fit pressure gauge to pressure test point.
3.  Light the fire (see next section).
4.  Turn control knob anti-clockwise to 

High

 position.

5.  When the control knob is in the 

High

 position, you should have a gas pressure of

19.5mbar ± 1.0mbar.

6.  Extinguish the fire by turning the low level control knob clockwise to the 

Off 

position.

7.  Remove the pressure gauge and replace the pressure test screw. Check again for gas

soundness.

8.  Fit the front fret by hooking the support lugs at each end through the slots in the front

casing (if using a Straxgas fret), or place an alternative front fret in front of the burner.

Note: 

If a fret from another manufacturer is being used, it must comply with the minimum free

area requirements of Fig. 1.

Lighting the fire

The appliance Data Badge is positioned in front of the burner behind the fret and carries the
control knob positions (Fig. 5).
The full lighting procedure is as follows:

Low level control version

1.  Push control knob in as far as possible on gas control.
2.  Turn knob anti-clockwise until a click is heard.  The knob will stop at the ignition

position and a spark should be seen at the tip of the ignition probe.  At the same time
the pilot flame should light.  KEEP THE KNOB PRESSED IN FOR 10 SECONDS.  If
the pilot should fail to light, turn the control knob clockwise to the 'off' position, wait 3
minutes and repeat the procedure.

3.  When the pilot flame is alight the control knob should be allowed to spring out slightly.

Turn the knob fully anti-clockwise to the high position.  The pilot flame should then
ignite the main fire.

4.  The height of the flames can be adjusted by turning the control knob between the low

and high positions.  Note that the knob 'latches' in position at either end of this
movement and must be pushed in slightly before it can be turned.

5.  To turn the fire off, depress the knob slightly and turn it to the pilot position.
6.  To completely extinguish the fire depress the knob slightly and turn to the 'Off'

position.

High level control version

1.  Proceed as for 1 and 2 above 'Lighting the fire'
2.  When the pilot flame is alight the control knob should be allowed to spring out slightly.

Turn the knob anticlockwise to the 'Run' position.

3.  The height of the flames can be adjusted by turning the knob at the top right hand side

of the fire between the high and low positions.

4.  To turn the fire off, turn the high level knob to the 'Off' position.
5.  To completely extinguish the fire depress the knob under the burner slightly and turn it

to the 'Off' position.

0087

Fig.  5 The data badge plate & test nipple

Summary of Contents for FLAIRE

Page 1: ...he Environment and Building Standards Scotland Consolidated Regulations issued by the Scottish Development Board Current Gas Safety Installation and Use Regulations Failure to install this appliance correctly could lead to prosecution and render the guarantee invalid Attention is drawn to the latest edition of the following standards BS1251 Specifications of open fireplace components BS5440 Part 1...

Page 2: ...lume for debris collection conforming to Fig 2 A pre cast block flue conforming to the requirements of BS1289 with a minimum cross sectional area of 12 000 sq mm and a minimum dimension of 60mm See Fig 2 for minimum depth requirements Ensure that mortar fangs between the blocks do not protrude into the flueway It is essential that the flue terminal does not restrict the flue flow and complies with...

Page 3: ...A 15mm gas supply pipe should be brought to within 1M of the fireplace opening The connection to the burner can be made from the right or left hand side by a concealed pipe from behind the burner to the restricter elbow on the left hand side of the burner Pierce the membrane grommet fitted in the back of the convection box and pass the gas supply pipe through ready for connection to the burner 8mm...

Page 4: ...Flaire Issue 1 3 29 06 01 Page 4 of 11 ...

Page 5: ...bolts and backnuts 3 2 Adjustable nipples with clamp screws 4 4 Screweyes and wall plugs 1 Mark out and drill 4 holes in the back of the opening to suit wall plugs supplied See the drawing for dimensions Insert the screweyes and align to allow the wires to pass through vertically 2 If the convector box has not been pre punched for the wire ropes drill the top and back shown in the drawing removing...

Page 6: ... ceramic components are fragile and should be handled with care Refer to Figs 4 and 5 for positioning of ceramic fibre blocks and coals 5 Place the back ceramic on the burner against the back of the convector firebox 6 Place a flat ceramic pad against each side of the firebox with the angled corner facing forward The pads are identified L and R Position them each side of the back ceramic 7 Slide t...

Page 7: ...k should be seen at the tip of the ignition probe At the same time the pilot flame should light KEEP THE KNOB PRESSED IN FOR 10 SECONDS If the pilot should fail to light turn the control knob clockwise to the off position wait 3 minutes and repeat the procedure 3 When the pilot flame is alight the control knob should be allowed to spring out slightly Turn the knob fully anti clockwise to the high ...

Page 8: ...er is aware that the ceramic blocks and coals must be located in accordance with the instructions and that the appliance should be serviced at regular intervals by a competent person to ensure continued safe operation 3 Explain that this appliance is fitted with an oxygen depletion sensor incorporated into the pilot body Should the fire repeatedly extinguish itself the cause should be sought and r...

Page 9: ...l polish IMPORTANT The paint finish is durable and heat resistant however it will be damaged if plaster cement or wallpaper paste is allowed to come into contact with it Protect the appliance during re building or decorating work Replacement of parts Before commencing any servicing always ensure that the fire is isolated from the gas supply and that the fire is cold After servicing always check fo...

Page 10: ...Check that the injector is parallel to the slots which retain the front coals 5 Reassemble in reverse order 6 Turn on the gas supply and check for soundness Replacement of ignition pilot assembly 1 Repeat operations 1 5 as described for Replacement of gas tap FSD piezo igniter 2 Disconnect thermocouple connection to the gas tap FSD piezo igniter 3 Disconnect pipe from base of pilot burner tube 4 P...

Page 11: ...cepted unless this product has been installed and operated strictly in accordance with these manufacturer s instructions U K Registered Design 2040268 British Patent Application 9414887 1 Design right reserved Legge Fabheat Ltd Fig 8 Quest outline drawing without trim ...

Reviews: