Voltage
1
Current
Power
Power
Factor
2
Bridging
Time
Interface
Topology
100–120 VAC
16 Amps
1500 VA
0.9
15 minutes
USB port
3
Compatible with
Windows
®
10
and Windows
®
7
Command-line
control
4
Double
conversion
online
220–240 VAC
8 Amps
Table 4 UPS requirements
The following UPS systems meet the above requirements:
•
Eaton PW9130G3000T–220–240 VAC
•
Eaton PW9130L2000T-XL–100–120 VAC
1
Single-phase; 50/60 Hz
2
Defined as the input-to-output ratio of the UPS.
3
UPS units that only connect to a serial communication port are not suitable.
4
Command-line control is necessary for the UPS software to execute a script in the printer software when shutting down.
Stratasys J826
Electrical Requirements
DOC-18005 Rev. E
©
2019-2020 Stratasys. All rights reserved.
14