Before welding displays the setting selected/being adjusted using the control knob (22). During
welding, displays welding current. The parameter setting displayed is indicated by the LEDs 15,
16, 17,19,20,21. If left inactive for several seconds, display will revert back to main welding
current setting.
Parameter Select/ Adjust Knob (22)
Switch between welding parameter settings by pressing this knob, adjust by turning the knob.
Value of the parameter selected will be shown on the digital multifunction display (18).
TIG
Parameter Setting
Pre gas flow setting indicator (1)
Controls the period shielding gas will flow for when the torch is triggered before the arc starts.
This purges the work area of atmospheric gas which could contaminate the weld before the weld
starts. Unit(S) and setting range (0-2S).
Start current setting indicator (2)
Available in 4T trigger mode, sets a welding current 5-100% of the main welding current
activated when the trigger is held on to ‘latch’ the trigger before the main weld current is started.
Once the trigger is released, the current will go through the upslope (3) period if it is set, to the
main welding current (4).
Up slope setting indicator (3)
When the trigger is activated, the welding current will increase gradually over the time selected
up to the set main welding current (4). Unit(S) and setting range (0-10S).
TIG welding current setting indicator (4)
14