Strand ACCLAIM LED CYC User Manual Download Page 16

USER MANU

AL

W

W

W

.S

TRANDLIGHTING.

C

O

M

A

C

CLAIM LED C

Y

C

  

16

GET

 

ALL

O

WED

SET

 

ALL

O

WED

RDM P

ARAMETER ID

S

V

AL

UE

C

OMMENT

ES

T

A

 

S

T

AND

ARD

REQUIRED /

 

IMPLEMENTED

Cat

egory – Sensors 0x0

2xx USE

SENSOR_DEFINITION

0x0

200

■■

SENSOR_V

AL

UE

0x0

201

Fan Speed and T

emper

atur

es

REC

ORD_SENSORS

0x0

20

2

Cat

egory - Dimmer Settings 0x0

3xx - FUTURE USE

■■

Dimmer Curv

e

0x0

343

Dimmer Curv

e Description

0x0

344

■■

Modulation Fr

equency

0x0

34

7

Modulation Fr

equency Description

0x0

348

Cat

egory - Po

w

er / Lamp Settings 0x04xx

■■

DEVICE_HOURS

0x0400

■■

LAMP_HOURS

0x0401

■■

LAMP_S

TRIKES

0x040

2

■■

LAMP_S

TA

T

E

0x040

3

■■

LAMP_ON_MODE

0x0404

■■

DEVICE_PO

WER_C

Y

CLES

0x0405

Cat

egory - Displa

y Settings 0x05xx

■■

DISPLA

Y_INVER

T

0x0500

■■

DISPLA

Y_LEVEL

0x0501

Cat

egory - C

o

n

fi

 gur

ation 

0x06xx

■■

PAN_INVER

T

0x0600

■■

TIL

T_INVER

T

0x0601

■■

PAN_TIL

T_S

W

A

P

0x060

2

■■

REAL_TIME_CL

OCK

0x060

3

Cat

egory - C

ontr

ol 0x10xx

■■

IDENTIFY_DEVICE

0x1000

■■

RESET_DEVICE

0x1001

■■

PO

WER_S

TA

T

E

0x1010

■■

PERF

ORM_SELFTES

T

0x10

20

All T

es

t, P

an/T

ilt, Enc

oder

SELF_TES

T_DESCRIPTION

0x10

21

CAPTURE PRESET

0x10

30

See E1-20_2010a

■■

PRESET PLA

YBA

CK

0x10

31

Table A

-7

 de

fi

 nes

Summary of Contents for ACCLAIM LED CYC

Page 1: ...ACCLAIM LED CYC USER MANUAL...

Page 2: ...documentation including DMX maps software and photometric reports are available for download on our website For more information on installing DMX512 control systems the following publication is avail...

Page 3: ...carefully inspect xture to ensure no damage has occurred during shipping Materials used in the manufacturing process can cause strong odors when the product is new These odors dissipate over time Prio...

Page 4: ...ssipate heat properly and can damage the luminaire Vari Lite LLC cannot be responsible for issues arising from non approved parts and accessories installed on or used with any Vari Lite LLC product Cu...

Page 5: ...ommunications As tested under this standard FCC 47CFR 15B clA CEI Issued 2009 10 01 Title 47 CFR Part 15 Subpart B Unintentional Radiators Class A Operation of this equipment in a residential area is...

Page 6: ...re shipping container or in its original packing box Be sure to clearly indicate the RMA number on all packing lists correspondence and ship ping labels If available please include a copy of your invo...

Page 7: ...cal patented reflector technology RDM controls and setup of fixture allows device settings to be configured remotely Color Calibration Multiple fan noise control modes and options Fresnel Profile Ligh...

Page 8: ...This maximum limit applies to the luminaire daisy chain only Your system or console may require fewer luminaires on a single data link path Consult your console documentation for more information To...

Page 9: ...menu mode automatically QUICK REFERENCE MENU KEY SHORTCUTS MENU KEY SHORTCUTS FUNCTION MENU ENTER Factory Defaults ENTER UP Shortcut to turn the fixture on at full output ENTER DOWN Shortcut to toggle...

Page 10: ...Change Model ZOOMSPOT PLE Fresnel SETTINGS LED Dimming Curve Square Law Default S Curve Linear Output Mode Standard Default Studio Whisper Color Calibration On Off Default Fan Mode On Auto Default Ref...

Page 11: ...N button to select LED Display On Time and Reset Defaults LED To select LED press the ENTER button to con rm Use the UP DOWN button to select Dimming Curve Output Mode Color Calibration Fan Mode and R...

Page 12: ...ode Version To select Version press the ENTER button to con rm Version will show on the display press the MENU button back to exit Fixture Hours To select Fixture Hours press the ENTER button to con r...

Page 13: ...55 Strobe speed Slow Fast 4 Red High 255 0 255 Red LED output level 5 Red Low 65535 0 65535 6 Green High 255 0 255 Green LED output level 7 Green Low 65535 0 65535 8 Blue High 255 0 255 Blue LED outpu...

Page 14: ...14 The following tables outline and describe all the RDM parameters IDs associated with the Acclaim LED Cyc lumi naire MODEL ID MANUFACTURER VENDOR ID MODEL DESCRIPTION PRODUCT CATEGORY 0x0314 Strand...

Page 15: ...TATUS_ID 0x0032 SUB_DEVICE_STATUS_REPORT_THRESHOLD 0x0033 Category RDM Information SUPPORTED_PARAMETERS 0x0050 PARAMETER_DESCRIPTION 0x0051 Category Product Information DEVICE_INFO 0x0060 PRODUCT_DETA...

Page 16: ...requency Description 0x0348 Category Power Lamp Settings 0x04xx DEVICE_HOURS 0x0400 LAMP_HOURS 0x0401 LAMP_STRIKES 0x0402 LAMP_STATE 0x0403 LAMP_ON_MODE 0x0404 DEVICE_POWER_CYCLES 0x0405 Category Disp...

Page 17: ...8AA5 Dim Snap On Off 0x8AA6 Color Snap On Off 0x8AA7 Auto Fan Mode On Off 0x8AA8 Gamma Shift 0x8AA9 Value range depends on options Tungsten Dimming On Off 0x8AAA CTB Correction On Off 0x8AAB LED Refre...

Page 18: ...u experience intermittent DMX signal problems check the pins on the connectors or on the PCB Test with a different DMX controller Check if the DMX cables run near or alongside high voltage cables that...

Page 19: ...e full speed LED Max out put approximately 60 of Standard output at appropriate level to ensure LED work at optimum temperature and output efficiency Fan speed remains at a constant speed and do not r...

Reviews: