WARNING:
This appliance must be earthed.
• This appliance must be fitted to a switch providing all pole disconnection with a minimum contact
separation of 3mm.
•
Access to the mains terminal is gained by removing the terminal block cover at the rear of the appli-
ance.
• Connection should be made with a suitable flexible cable with a minimum temperature rating of
70°C.
•
First strip the wires then push the cable through the cable clamp.
•
Connect the cable to the terminal block and tighten the cable clamp screws - see diagram.
• Refit the terminal box cover.
• Sufficient cable should be used to allow the cooker to be pulled out, but must hang clear of the floor
so it does not become twisted or trapped when the cooker is pushed back.
The terminal block screws and clamps can be damaged by excessive tightening and untightening. DO
NOT USE POWER TOOLS!
Single Phase Connection (230V ac 50Hz)
4
5
2
3
6
1
N
L
Shorting
Links
Shorting
Link
Connect cable to terminal block:
L to terminal 2.
N to terminal 5.
Earth to terminal.
Ensure shorting links are fitted between
terminals 1-2, 2-3, 4-5 and 5-6.
Ensure all screws are fully tightened.
Cable
Clamp
Three Phase Connection (230/400V 3N ac 50Hz)
4
5
2
3
6
1
N
Shorting
Links
Connect cable to terminal block:
Remove shorting links 1-2 and 2-3
L1, L2 and L3 to terminals 1, 2 and 3.
N to terminal 5.
Earth to terminal.
Ensure shorting links are fitted between
terminals 4-5 and 5-6.
Ensure all screws are fully tightened.
Cable
Clamp
L1 L2 L3
CONNECT TO THE ELECTRICITY SUPPLY - TERMINAL BLOCK
Summary of Contents for ST RICH DX S1000Ei
Page 1: ...USER GUIDE A commitment to Stoves Range Electric Induction Part Number 083770500...
Page 46: ...How to position the Splitter USING THE SPLITTER 90CM DELUXE ONLY...
Page 60: ...Removing Telescopic shelves USING YOUR APPLIANCE...
Page 71: ...Please keep this handbook for future reference or for anyone else who may use the appliance...