Step 6: Commissioning
Burner aeration
All burners have fixed aeration and no
adjustment is possible.
Pressure setting
G20 Natural Gas @ 20 mbar
G30 Butane @ 28-30 mbar
G31 Propane @ 37 mbar
The pressure test point is on the top of
the manifold inlet block.
Programmer
The programmer must be set to the
time of day before the main oven
can be used manually - see the
‘Programmer / Clock’ section to ‘Set
the time of day’.
Electrical Systems Check
In the event of an electrical fault, the
preliminary electrical system check
(earth continuity, short circuit, polarity
and resistance to earth) must be
carried out. There is also a Fault Finding
Section in the Servicing Instructions.
Ignition
The automatic ignition continues to
spark for a short time after the burner
flame has lit until the flame is
established.
Grill
1. The door must be open for the grill
burners to ignite.
2. Turn clockwise to the grill setting.
3. Close the door and check that the
burner goes out. The grill burner
will re-ignite when the door is
opened again.
Main Oven
1. The door must be closed for the
oven burner(s) to ignite. The oven
burner will go out when the door is
opened but will re-light when the
door is closed again.
2. Turn the oven control knob to the
required setting.
Top Oven
1. Turn the control knob to the
required setting.
Before leaving the installation
Show the customer how to ignite the
oven and grill and give them this
handbook.
Thank you.