Data badge
Front frame
Type of gas
This appliance must only be used with
Natural Gas.
Gas category
Natural Gas -
I
2H
, G20 @ 20mbar
Pressure setting
20 mbar
Pressure test point - use oven injector
Ignition
2 outlet re-ignition generator
Appliance class
Class 3, Built-In Oven & Grill
Light bulbs
2 grill & 2 oven
4 x 25W
Electrical supply
230 - 240V ~ 50Hz
Grill
•
Burner -
Bray surface combustion
type
•
Spark gaps
3 - 4mm
•
Nominal Rate Qn
2.25kW
•
Injector (Copreci)
1.12mm
Oven
•
Burner -
Bray type burner, sheet
steel body, stainless steel flame strip
•
Nominal Rate Qn
2.5kW
•
Injector
1.15mm
Total Heat Input
∑
Qn 4.75kW
Countries of destination
GB - Great Britain, IE - Ireland
40
TECHNICAL DATA