Step 7: Commissioning
Burner aeration
All burners have fixed aeration and no
adjustment is possible.
Pressure setting
G20 Natural Gas @ 20 mbar
Pressure test point - use oven injector.
Programmer
The programmer / clock must be set to
the time of day before the oven can
be used. See “Programmer / Clock”
section to
‘Set the Time of Day’
.
Electrical systems check
In the event of an electrical fault the
preliminary electrical system check
(earth continuity, short circuit, polarity
and resistance to earth) must be car-
ried out. There is also a fault finding
section in the servicing instructions.
Ignition
The automatic ignition continues to
spark for a short time after the burner
has lit until the flame is established.
Oven
1. Push in and turn the control knob
anticlockwise to Gas Mark 9.
2. Adjust to the required setting.
3. The burner may not come on to full
rate unless the oven door is
closed.
Note:
The oven burner operates at
a low rate for up to 60 seconds
until the flame supervision device
opens and full gas rate is
obtained.
Grill
1. Open the grill door.
2. Push in and turn the control knob
anticlockwise to the grill setting.
The grill light will come on
automatically.
Before leaving the installation
Show the customer how to ignite the
oven and grill, and give them this book.
Thank you.
33