7.1. Installation
Do not leave the device unat-
tended during operation. Put
the VOLCANO CLASSIC on a
Fat and stable surface. Check whether
the mains voltage corresponds to the
voltage rating stated on the device. The
power cord and the plug must be in a
perfect condition. Only connect the
VOLCANO CLASSIC to a properly in-
stalled (grounded) socket. It is manda-
tory to electrically ground the Hot Air
Generator. The manufacturer will not
bear any responsibility whatsoever if
this accident prevention measure is not
taken.
7.2. Heating Up
To switch on the heater, push the rock-
er switch labeled “HEAT“. The rocker
switch will light up, signaling that the
heater is in operation. At the same time,
the yellow control lamp will be signaling
that the device is heating up. This heat-
ing process of the heat exchanger can
take up to 5 minutes depending upon
the chosen temperature.
As soon as the yellow control lamp
turns off, the set temperature has
been reached, and the heat exchang-
er‘s warming process is complete. If
the temperature in the heat exchanger
drops, the heat exchanger will automat-
ically heat up, which is signaled by the
yellow control lamp lighting up again.
7. OPER ATING T HE VOLCA NO CL A S S IC
The vaporization temperature may Fuc
-
tuate about ± 5°C (± 9°F) related to the
indicated values because of the heat-
ing and cool off process of the heat
exchanger. For example at level 6 from
185°C up to 195°C (365°F up to 383°F).
Vaporization Temperature Table
7.3. Temperature Setting
63
en
fr
es
it
nl
de