Page 3: ...th quick connector silicon tube and air valve filter 1 canister of UNIQUE fluid 2l 1 manual As an option XLR remote for analogue control delivered without cable Diverter Flightcase Hanging set Please check whether all the products you ordered are supplied ...

Page 4: ...ices 10 5 4 1 Control via DMX 512 5 4 1 1 Adjusting the DMX start address 5 4 1 2 Adjusting the pump and the fan 5 4 2 Control via 0 10 Volt DC 5 4 2 1 Adjusting the pump and the fan 5 4 3 Stand alone mode 5 4 3 1 Adjusting the pump and the fan 5 4 4 Control via Haze Density Control System HDCS 5 4 4 1 Using the Profile 5 4 5 Working with the internal Timer 5 4 5 1 Autostart 5 5 Wiring of the sock...

Page 5: ...e creating the right atmosphere and is providing excellent support for lighting effects The pump and the fan are fully and separately controllable giving the Unique 2 1 a good level of noise reduction The machine can therefore be used in fields of operation where any sound is undesirable or causes disturbance The ready mixed fluid available in canisters of 2 litres guarantees a trouble free workin...

Page 6: ... you have accidentally swallowed some fluid i z z w z z z yw yw w w zD c z w z dispose of it according to regulations UNIQUE fluid is completely water soluble and biodegradable w wy w z y D Artificially made fog can be produced in many different ways The method used here to produce fog with a device which works according to the vaporizer principle is the most harmless one No case has so far been r...

Page 7: ...fragrances with this machine UNIQUE 2 1 Serial no Rear view 2 6 Front view 7 Nozzle Vapour and nozzle area extremely hot Do not touch Do not cover the nozzle area anddonotconnectaducting Vapour and nozzle area extremely hot Do not touch Do not cover the nozzle area and do not connect a ducting UNIQUE 2 1 Look Solutions 3 Description of the parts 1 Mains cable 2 XLR sockets for DMX in out 3 XLR soc...

Page 8: ...7 3 Description of the parts 11 10 12 9 13 Tank lid 9 Brass collar 10 Tank lid 11 Brass coupling 12 Fluid filter 13 Check valve ...

Page 9: ...ollar 9 until you hear a click The brass collar is now locked firmly 4 Fluid 4 2 Changing the fluid bottle The ready to use UNIQUE Fluid for use in the Unique 2 1 is available in 2 litre canisters from your local dealer Fluid also comes in 10 and 25 litre canisters and barrels with 220 litres j w w x C w y w kd_gk C z x zD Use of other liquids will void the manufacturer s warranty and can be dange...

Page 10: ...from vibrations be a non flammable place or surrounding be well ventilated with haze free air keeping the ambient operating temperature between 10 C and 40 C 50 F and 105 F and the relative humidity below 80 5 Operating the Unique 2 1 5 2 Putting into operation Warning Never connect the Unique2 to a dimmer or switchpack This may destroy the machine a Connect the power plug to the mains supply Make...

Page 11: ...g To cut this process short the air pump works with full power for a short time and also put all remaining fluid out of the vaporizer The remaining fluid will maybe come out as a bigger haze cloud This is normal and no failure of the machine When the heater is cooled down a red decimal point will ap pear on the right bottom edge of the display b When you switch off the DMX signal the machine will ...

Page 12: ...0V DC and Stand alone operation Please noteP o yw v z z c z Cx y c D The Mode button has to be pressed only momentarily If the Mode button is pressed more than two Seconds the machine will change into the Timer Mode see point 5 4 5 5 4 1 Operating via DMX 512 Connecting the Unique 2 1 to a DMX desk use the XLR socket 2 beside the control panel As soon as the machine receives a correct DMX signal t...

Page 13: ...ar on the LED display 17 see Fig 1 Put the pump up to 99 b Press the Mode button 14 at the control panel until an F and two figures appear on the LED display 17 see Fig 2 c Adjust the desired data 1 99 by pressing the Up or Down button 15 d The data for the pump can be regulated adjusted via the turnable button on the cable remote and the fader on your analogue desk 5 Operating the Unique 2 1 5 4 ...

Page 14: ...an be used in the Stand alone mode In this mode all data for the pump and the fan must be adjusted directly at the machine 5 4 4 Haze Density Control System HDCS Fig 6 Adjusting the Pause Pre Runtime Fig 7 Adjusting the pump Fig 8 Start the profile Fig 9 Quit the profile DMXIN ACTIVE 888 ADDRESS À 088 PUMP À 88 FAN 0 PAUSE MIN À FOGTIME SEC PAUSE À LEVEL A À LEVEL B TIMER PROFILE 1 0 1 DMXIN ACTIV...

Page 15: ... 10 Minutes high output pump and fan shall go down automatically to a lower step and fill the stage with haze for another hour setting 5 6 7 See diagram on page 15 also w f c z x w z qGJsB f w w z w D 4 b Press the Enter button 16 once to switch to the HDCS Menu The red Timer Profile LED 20 will be lit c Adjust settings 1 to 7 according to the chart on page 15 using the Up Down buttons 15 and pres...

Page 16: ...AN 0 PAUSE MIN À FOGTIME SEC PAUSE À LEVEL A À LEVEL B TIMER PROFILE F 0 5 DMXIN ACTIVE 888 ADDRESS À 088 PUMP À 88 FAN 0 PAUSE MIN À FOGTIME SEC PAUSE À LEVEL A À LEVEL B TIMER PROFILE P 0 1 DMXIN ACTIVE 888 ADDRESS À 088 PUMP À 88 FAN 0 PAUSE MIN À FOGTIME SEC PAUSE À LEVEL A À LEVEL B TIMER PROFILE P 1 5 DMXIN ACTIVE 888 ADDRESS À 088 PUMP À 88 FAN 0 PAUSE MIN À FOGTIME SEC PAUSE À LEVEL A À LE...

Page 17: ...blink as soon as the machine has switched to the Timer Mode As long as the timer is in operation the red Timer Profile LED blinks The adjusting of the output haze time or wait time is the same as in the Standard Menu This means you have to press the Mode button repeatedly until you reach the required function With the Up Down buttons you can adjust the required functions then press the Enter butto...

Page 18: ...mage the vaporizer We cannot grant warranty in this case 7 Troubleshooting Trouble The pump runs but little or no haze is produced Cause The pump sucks no or too little fluid Check whether the canister is empty Check whether the brass collar is properly connected with the brass coupling Check whether the fluid filter in the canister is clogged Check whether the fluid tube is twisted or defective T...

Page 19: ...your local dealer 8 Specifications E 1 E 8 E 4 Procedure Haze generator without compressor Power requirement 1500 Watt Voltage 230V 50Hz also available with 120 V 60 Hz and with 90 V 60 Hz Warm up time approx 60 seconds Fluid tank capacity 2 litre Internal fan 6000 l min Haze output adjustable in 99 steps 1 steps Haze density variable Haze duration continuous output Control DMX 512 0 10 V analog T...

Page 20: ...r property 3 The customer loses all rights for guarantee services if any repairs or adjustments are done to the units by unauthorized persons and or if spare parts are used which are nor approved by D j w w y w z w w kd_gk C z have been used or if units are sent to us with full fluid bottles Also non compliance with the instructions in this manual or mistakes by incorrect handling treating of the ...