background image

1 x 1770 x 780mm door sheet.
2 x 1770mm “U” channels.
2 x 780mm “U” channels.
1 x 310mm door plate.
Hinges.
Door bracing.

If you choose to vary from these instructions 

your warranty will be impaired.

2

1. 

Attach the 780mm “U” channels 

J

 to 

the top and bottom of the door sheet 

A

 at the centre ribs only.

2. 

Attach the 1770mm “U” channels 

H

 to 

the door sheet 

A

 through the top and 

bottom channels 

J

 at the four corners.

3. 

Attach the door plate 

M

 in the centre of 

the door sheet, slipping it under the two 

side “U” channels and fixing it to the 

sheet ribs and the side “U” channels.

4. 

Attach the hinges 

N

 approx 150mm 

from the top and bottom of the door 

through the “U” channels. The fixings 

should be centred on the side “U” 

channels.

5. 

Turn the door over and fix the four 

corners through all the “U” channels 

and fit the door bracing from the bottom 

corner to the opposite centre to the top 

corner.  (step 2 below).

Step 1: 

Door Assembly

A

A

N

O

H

H

H

J

J

J

M

You will need:

1. 

Attach the first “Z” door jamb 

L

 to the 

740mm sheet 

B

 on the rib with the 

narrow pan. Attach the other “Z” door 

jamb to the 740mm sheet 

B

.

2. 

Lay the premade door face down on the 

740mm sheet 

B

 approx 30mm up from 

the bottom and down from the top.

3. 

Check the door is centralised on the 

sheet (top and bottom). Fix the hinges 

through the side of  the “Z” door jamb 

L

, raising the door about 4mm off the 

"Z" door jamb.

Step 2: 

Hanging the 

door

B

L

2 x 1830 x 740mm sheet.
1830mm “Z” door jambs.

You will need:

M

N

30mm

4mm

gap

Narrow pan

If you need advice, call us FREE on 0800 807 433  

or email us at [email protected]

150mm

Hinges should 
protrude over the 
top of the channel

Summary of Contents for rite 5

Page 1: ...ing 1 plastic wrapped package Some parts have sharp edges and should be handled very carefully We recommend the use of protective gloves and footwear when assembling DO NOT attempt to erect this shed in windy weather All dimensions are approximate rite 5 Tools required Battery or electric drill 3 3mm 1 8th inch drill bit Screwdriver and riveter Tape measure Ladder Non slip gloves good shoes and go...

Page 2: ...gs in the pans as close to the ribs as possible for added strength Ribs will always protrude to the outside of the shed Extra internal fixings are strongly recommended in high wind areas If you need advice call us FREE on 0800 807 433 or email us at info storite co nz 1 x 1770 x 780mm door sheet 2 x 1830 x 740mm sheets Beside door front 3 x 1830 x 780mm back wall 6 x 1200mm x 780mm sheets roof 6 x...

Page 3: ... channels 5 Turn the door over and fix the four corners through all the U channels and fit the door bracing from the bottom corner to the opposite centre to the top corner step 2 below Step 1 Door Assembly A A N O H H H J J J M You will need 1 Attach the first Z door jamb L to the 740mm sheet B on the rib with the narrow pan Attach the other Z door jamb to the 740mm sheet B 2 Lay the premade door ...

Page 4: ...top Put the padbolt on the door before erecting the panels It will stop the door swinging around diagram 1 Channels will come short of the ends of the sheeting by 10 15mm on all panels Fix through the top and bottom of the channels into the door jamb and spacer The door jamb goes on inside of the channel The higher side of the channel goes to the inside of the shed It is very important to include ...

Page 5: ...e 2255mm U channels F 3 Fix the channels at every second rib but not the corners at this stage 4 Place the short flange of the first L flashing K on top of the rib at one end Make sure the ends are flush with the sheeting diagram 1 and put one fixing in the centre to hold the L flashing Fix the corners through the channels and one more between the corner and the centre fixing 5 Perform the same at...

Page 6: ... at each end of the roof panel with the Ridge beam attached waft it over top of your upright walls and lower down on top Have your helping hand go inside and make sure the roof panel is centralised by having the ridge beam sitting right on the apex of the channel at the peak of the end wall Fix the L through the top channel to both end walls at the 1st rib in from the lowest corner making sure it ...

Page 7: ...lease ask your nearest hardware store for further details Internal dimensions for the RITE 5 2235mm x 2235mm Boxing Diagram shed recess 20mm 25mm 20mm 25mm 1 x 1 8mm Bolt set into concrete Internal Dimensions Approx 25mm recess around the outside 100mm 25mm 2235mm 2235mm approx 25mm 25mm If you need advice call us FREE on 0800 807 433 or email us at info storite co nz floor board Important It is e...

Page 8: ...od photo of your finished shed with your details To help you we have listed some questions that you may like to answer There is no need to type every question only the question number and your answers are necessary 1 Where did you find out about our sheds 2 Where did you purchase your shed Was the sales person helpful 3 Were you happy with the delivery of your shed and your overall purchase experi...

Reviews: