![Storch 600800 Operating Manual Download Page 27](http://html1.mh-extra.com/html/storch/600800/600800_operating-manual_1382498027.webp)
27
Safety information
The device must be used only by trained persons.
Only pump non-pigmented media. Do not use nitro- and low-molecular hydrocarbons, aggressive acids or alkalis. The
default pressure hose is resistant to solvents to a limited extent. If you intend to use solvent-containing media fre-
quently, use an EPDM pressure hose. The motors of the standard version are not ex-protected.
As standard, the device is equipped with a three-pin plug. If your electrical outlet does not match this plug, have a
professional change it. Couplings and connecting cables must be splash-proof. Observe the voltage. Use only 230 Volt
connectors. Use the device only if the power cables are in perfect condition.
The device possesses a voltage range which can pose an electrical hazard to humans and animals. It should only be un-
screwed and / or disassembled by authorised personnel. Similarly, maintenance and repair work should only be conducted
by electrical specialists and authorised service centres. The buyer / user operates the device at their own risk and under
their own responsibility.
Commissioning
1. Check the oil level before every use. To do so, remove the oval rubber cap. The oil level must be at the oil level
mark in the spout. If oil needs topping up, use one of the following oils only: FUCHS RENOLIN UNISYN CLP 150,
BP ENERGOL SG 150, BP ENERSYN SG 15, SHELL TIVOLA WA or MOBIL SHC 629.
2. Check whether suction and return hoses are attached securely. Then connect the pressure hose with the spray gun
and pump.
3. Securely attach the suction and return lines to the spray container using the hose clamp. Prevent air infiltration into
the suction line.
4. The pressure control valve (red knob) must be set to minimal pressure before every use (turn counter-clockwise).
Only increase the pressure while pumping and the spray gun is open. The pressure of the pump is adjusted in three
increments up to 6 bar.
To learn how to spray, we recommend you use water to practice for the first time.
As standard, the spray gun is equipped with a flat-spray nozzle (blue). Once you have finished spraying, set the control
valve on the pump to minimal pressure. Pull the suction hose out of the container so that the pump can run empty.
Cleanup
Let the system run completely empty. Place the suction hose in a container with a suitable rinse medium, place the
return hose in a receiving tank and thoroughly rinse the pump and pressure hose. For the final rinse we recommend you
use soapy water (Pril or the like). Never leave the medium inside the pump as otherwise valve components may stick
together and seals be damaged.
If the pump has not been cleaned correctly, the valve heads may stick to the valve seats. In this case, open the valve
fittings (red screw heads on the side of the pump housing with a size 17 open end spanner), free the heads from the
seats, clean, place the heads back in position and tighten the screw connections hand-tight.
Translation of the original instruction