Chapter 2. Creating an Initial Configuration
EK–SMRA3–IG. C01
2–13
Next, verify the StorageSets you have configured:
SWXRC> SHOW STORAGESETS
The controller responds with a display similar to that shown below:
Name
StorageSet
Uses
Used by
STRIPE_MIRROR
stripeset
MIRROR_SET_3
D500
MIRROR_SET_4
STRIPE_SET_1
stripeset
DISK110
D2
DISK210
DISK310
MIRROR_SET_1
mirrorset
DISK120
D400
DISK220
MIRROR_SET_3
mirrorset
DISK320
STRIPE_MIRROR
DISK420
MIRROR_SET_4
mirrorset
DISK520
STRIPE_MIRROR
DISK620
RAID_SET_1
raidset
DISK100
D0
DISK200
DISK300
RAID_SET_2
raidset
DISK400
D1
DISK500
DISK600
SPARESET
spareset
DISK610
FAILEDSET
failedset
JBOD devices are not displayed in this report. To display JBOD devices, enter the following:
SWXCR> SHOW DEVICES
Record the above information in the following table. In the event of a controller failure, the
information that is recorded here will assist you in reconstruction of the storageset on your
RAID Array 410.